System inertia
This is a parameter which adjusts the reaction time of the ad-
justment algorithm, to be associated with inertia or with the
size and type of building and the heating system.
Flow Temp. min. set
It is the lower limit of the calculated flow temperature (use-
ful in the case of low efficiency systems with low calculated
temperatures)
Antifreeze enable
YES setting
: enable the antifreeze protection program
NO setting: the heating will remain off when in the function
mode OFF, SUMMER and in periods of Reduced mode AUTO if
the room sensor is disabled.
Antifreeze set
This is the room temperature (antifreeze) below which the de-
vice makes a heating request at the minimum flow set. The
request remains active until the room temperature has ex-
ceeded the "antifreeze tempe 0.6°C”
Room probe offset
This is the value used to correct the room temperature read-
ing by the sensor inside the device.
4.3
Settings from the MODE button
From the
“main screen”
Gi 20 Mar 2014
Zona
10:30
Off
Menu
Modo
– Press the button
Mode
to go into the screen to select
“Function mode”
– Rotate the encoder
to select one Mode (eg. “Winter”)
Esc
Back
Winter
Off
Summer
Hot water
MAN 40°C
Heating
MAN 20.0°C
Holiday function OFF
– Press the encoder
click
to confirm the highlighted
“Mode”
and go into the
“rows”
Esc
Back
Winter
Hot water
MAN 40°C
Heating
MAN 20.0°C
Holiday function OFF
– Rotate the encoder
to select
“Heating”
Summary of Contents for 8092280
Page 71: ...71 EL Sime HOME 8092280 1312 a f d m...
Page 73: ...73 EL 1 1 1 m ESD ESD 1 2 d...
Page 75: ...75 EL 2 4 Sime HOME 1 2 3 1 2 3 2 Bus 4 OpenTherm 5 2 x 0 75 mm2 max 50 m 4 5 2 6 7 2 6 7...
Page 76: ...76 EL 3 2 1 3 2 m 2 3...
Page 77: ...77 EL 3 3 1 Sime HOME bus Open Therm standard Sime HOME Off 4 24 3 2 encoder encoder...
Page 93: ...93 EL 5 5 1 2012 19 2012 19 49 2014 d...
Page 95: ...95...