Room probe run
YES setting
: the heating system heat request only occurs if the
room temperature is below the set room set point.
NO setting: the heating system heat request is constantly pre-
sent in “Manual” and “AUTO COMFORT” mode. The request is
not present in other modes.
Room probe modul.
YES setting
: the flow temperature is modulated on the basis
of the offset between the real room temperature, measured
by the sensor inside the device, and the programmed room
temperature
NO setting: the flow temperature will be maintained at the
maximum allowed during the request period (backlash man-
agement).
Ext. probe modul.
YES setting
: the maximum delivery temperature (and the mod-
ulated temperature if modulation has been enabled with the
room sensor) is adjusted on the basis of the external tem-
perature (if there is an external sensor), taking into account
the values set for the weather comp. curve and corresponding
Offset.
Weather comp. curve
The incline of the selected weather comp. curve used to mod-
ulate the flow temperature on the basis of the external tem-
perature. The upper and lower limits for the curve depend on
the boiler delivery limits.
Heating temperature
20
15
10
5
0
-10
-15
-5
-20
80
90
70
60
50
40
30
20
°C
°C
K=9
K=7
K=8
K=5
K=6
K=3
K=4
K=2
K=1
External temperature
Weather comp. offset
This is the vertical movement of the weather comp. curve
which is used to correct the calculated delivery temperature.
Backlash off temp.
It is the value to be added to the room temperature above
which the device will switch off the request, exclusively during
backlash adjustment (modulation with room sensor disabled,
but with room probe use enabled)
4.2.5 Technical specifications
Summary of Contents for 8092280
Page 71: ...71 EL Sime HOME 8092280 1312 a f d m...
Page 73: ...73 EL 1 1 1 m ESD ESD 1 2 d...
Page 75: ...75 EL 2 4 Sime HOME 1 2 3 1 2 3 2 Bus 4 OpenTherm 5 2 x 0 75 mm2 max 50 m 4 5 2 6 7 2 6 7...
Page 76: ...76 EL 3 2 1 3 2 m 2 3...
Page 77: ...77 EL 3 3 1 Sime HOME bus Open Therm standard Sime HOME Off 4 24 3 2 encoder encoder...
Page 93: ...93 EL 5 5 1 2012 19 2012 19 49 2014 d...
Page 95: ...95...