background image

1. Intended use

SimCPR

®

Pro Trainer

is a training tool for CPR-rescuers to optimize their CPR-skills.

Indication of use:

This device is only to be used for training chest compressions for adults (> 12 years) and for
SimCPR

®

-feedback simulation.

2. Description

SimCPR

®

Pro Trainer shows users if chest compressions are compliant with the international

CPR-guidelines on depth and rate.
When the green LED is continuously on, compression-decompression is at least 2 inches
(5cm) and rate between 100-120 bpm.

The rescuer wears the

SimCPR® Pro Trainer

on the wrist of the left or right hand.
As educated, the rescuer always keeps
contact with the chest of the manikin during
compressions and does not lean on the chest
after release (decompression).
If the

SimCPR

®

Pro Trainer

is worn on the

upper hand, this hand should keep in contact

with the underlying hand. This ensures that the results of the depth measurements are
accurate.

Ensure that the wristband is tight enough around the wrist to ensure that there is no
slackness, so that the wristband exactly follows the movement of the wrist.
In case the LED lights are not clearly visible during CPR, the

Trainer

can also be worn on the

back of the upper hand. In this way the first responder is looking straight into the LED’s.

Feedback on CPR quality is provided by a red and green LED light. The frequency of the
flashing of the LED lights indicates the correct chest compression rate (110/min).

The red flashing LED indicates that compression-decompression movement is not enough (<
5 cm/2 inches). This means chest compressions are not deep enough and/or there is no full
recoil of the chest.

The green flashing LED indicates that compression-decompression depth is adequate (≥ 5
cm/2 inches). When the green LED is continuously on, both debt (≥ 5cm/2 inches) and
tempo (100-120bpm) are correct.
This form of simple feedback optimizes the quality of chest compressions.

1

1

Lu, T.C., Chang, Y.T., Ho, T.W., Chen, Y., Lee, Y.T., Wang, Y.S. et al. Using a smartwatch with real-time feedback imPro

Trainerves the delivery of high-quality cardiopulmonary resuscitation by healthcare Pro Trainerfessionals.

Resuscitation

. 2019;

140: 16–22

3

Summary of Contents for PRO

Page 1: ...SimCPR Pro Trainer User Manual Read this carefully before use SimCPR Pro Trainer is not a medical device and is only to be used for CPR training SimCPRR Pro Trainer v1 2 Eng ...

Page 2: ... 3 2 Description 3 3 Functionality 4 4 Use 4 5 Periodic battery check and replacement 5 6 Background information de compression 7 7 Troubleshooting 7 8 Trainer app 7 9 Technical specification 8 10 Explanation of symbols 9 2 ...

Page 3: ... wrist to ensure that there is no slackness so that the wristband exactly follows the movement of the wrist In case the LED lights are not clearly visible during CPR the Trainer can also be worn on the back of the upper hand In this way the first responder is looking straight into the LED s Feedback on CPR quality is provided by a red and green LED light The frequency of the flashing of the LED li...

Page 4: ...ng on adult victims or children older than 12 years The training device can be used on every CPR training manikin that is able to be compressed at least 5cm 2inches The rescuer wears the trainer on his her preferred wrist making sure that the 2 LED lights are clearly visible during chest compressions The wristband should be tight enough around the wrist to ensure that there is no slackness so that...

Page 5: ...g hours To save battery life the SimCPR Pro Trainer automatically switches off after 2 minutes of not using it You can check battery capacity quickly anytime by switching the SimCPR Pro Trainer on and then off again After you switch it off by pressing the ON OFF button for at least 3 seconds the green or red LED will light up briefly If the green LED lights up there is sufficient battery charge av...

Page 6: ... waste station 5 Insert a new 3V battery CR2032 in the same way side up 6 Place back the sensor this is only possible in one way and push the battery down for optimal LED light effect 7 Place back the white cover with light guides also this is only possible in one way 8 Place back the upper red part fits one way and finally put the 4 screws back Turn the SimCPR Pro Trainer on and check if the LED ...

Page 7: ...SimCPR Pro Trainer does not switch on red LED does not flash ON OFF button has not been pressed hard enough Press the ON OFF button firmly until you hear a click Battery is flat Replace the battery Device is defective Contact your dealer Green LED does not flash Your compressions are not deep enough Press the manikin deeper 5 cm 2 inches Check the manual of the manikin to see if it can be pushed d...

Page 8: ...ED starts flashing again Depth accuracy accelerometer 5 Model SimCPR Pro Trainer Catalog number 98091 Dimensions 45x40x20 mm 1 77 x1 57 x0 97 Weight 23 g Batteries CR2032 3V Lithium Battery lifetime 6 years 100 hours operational use User conditions Temperature Between 0 C and 40 C Relative humidity 0 to 90 RH Atmospheric pressure 860 hPa to 1060 hPa Protection against dust water IP54 Storage SimCP...

Page 9: ...10 Explanation of symbols ON OFF button CE mark Manufacturer details Manual Reference number LOT number WEEE symbol waste processing FCC label QR code for unique identification 9 ...

Reviews: