background image

6

A E R O S T A T   S E N T R Y

5 1 0 0 6 0 0   R e v .   H

Enclosure:

  Steel

Finish: 

 Power Coated

Weight: 

 17.5 lbs (7.9 kg)

Size: 

 15 3/8” W x 4 1/2” H x 8 1/8 D

          (39.1 cm W x 11.4 cm H x 
          20.6 cm D)

Bench Stand Feet:

Nonconductive, nonstaining polymer

Air Filter:

30 PPI open Cell Polyurethane Foam Aluminum Housing

Ion Output (discharge time):

Fan Speed – High

1 ft.

2 ft.

3 ft.

4 ft.

4

5

6

8

1 ft.

1.5

2.5

4

5.5

Center Line

4

5

6

8

1 ft.

Fan Speed – Medium

6

7

9

11

1 ft.

1.7

3.5

5

7

Center Line

6

7

9

11

1  ft

Fan Speed – Low

8

9

10

12

1 ft.

2

5

7

9

Center Line

8

9

10

12

1 ft.

Offset voltage and discharge time determined as per EOS/ESD Standard No. 
3 using 6” x 6”, 20 pF plate (Charged Plate Monitor).  Discharge times are in 
seconds from 1000 volts to 100 volts.

NOTE – 

Discharge times for high speed are 10% longer for 230V, 50 Hz.

Summary of Contents for Aerostat Sentry 4003000

Page 1: ...AEROSTAT SENTRY 5100600 Rev H Aerostat Sentry Ionizing Blower INSTALLATION AND OPERATING INSTRUCTIONS...

Page 2: ...AEROSTAT SENTRY 5100600 Rev H TABLE OF CONTENTS 1 DESCRIPTION 3 2 SAFETY 4 3 SPECIFICATIONS 5 4 INSTALLATION 7 5 OPERATION 8 6 MAINTENANCE 9 7 REPLACEMENT PARTS 10 8 WARRANTY 11...

Page 3: ...ield that injects alternating polarity ions into the airflow The shaped airflow exiting the Sentry carries these ions over a broad area for static elimination The ionizer of the Sentry features a bala...

Page 4: ...m being returned should be shipped prepaid and packed to provide adequate protection 2 SAFETY NOTE Statements identified with a NOTE indicate precautions necessary to avoid potential equipment failure...

Page 5: ...elocity Fan Speed 1 ft 2 ft 3 ft 4 ft Low 600 300 180 150 Medium 800 400 220 180 High 1000 500 250 200 Velocity in FPM measured at centerline of air stream Air Flow characteristics 3 x 6 Area Coverage...

Page 6: ...t discharge time Fan Speed High 1 ft 2 ft 3 ft 4 ft 4 5 6 8 1 ft 1 5 2 5 4 5 5 Center Line 4 5 6 8 1 ft Fan Speed Medium 6 7 9 11 1 ft 1 7 3 5 5 7 Center Line 6 7 9 11 1 ft Fan Speed Low 8 9 10 12 1 f...

Page 7: ...ration Plug the unit into a standard 2 terminal double grounded receptacle To set the unit up in a bench stand configuration secure the feet to the mounting yoke 1 Place the feet on a table top with t...

Page 8: ...he Sentry produces an ionized air stream that covers a large area uniformly The time required to neutralize a static charge on an item in this area depends on many factors Two important factors are di...

Page 9: ...ers 1 Grasp the emitter cleaner between thumb and forefinger 2 Sweep back and forth across the ionized air outlet Recommended frequency of cleaning is once a week The ionized air outlet should remain...

Page 10: ...and again approach the surface with the tape If it has been neutralized it will not attract NOTE When performing this procedure do not use a plastic surface such as acrylic as the surface itself may b...

Page 11: ...h 6 4670700 Brush 7 4401510 Ionizer Duct Standoff long 8 4401591 Ionizer Duct Standoff short 9 4103940 Line Cord Assembly 120 V 9 4104393 Line Cord Assembly 230 V 10 4610531 Rocker Switch 11 4610758 3...

Page 12: ...any goods for any reason contact Simco Ion Customer Service at 215 822 6401 for a Return Authorization Number This number must accompany all returned items This warranty does not apply when the equip...

Reviews: