background image

11

A E R O S T A T   S E N T R Y

5 1 0 0 6 0 0   R e v .   H

7. REPLACEMENT PARTS

I

tem #

Part Number

Description

1

4670785

Handle

2

4500111

Lid

3

5050284

3-Speed Blower, 120 V

3

5050294

3-Speed Blower, 230 V

4

4630155

H.V. Transformer with Leads, 120 V

4

4630157

H.V. Transformer with Leads, 230 V

5

4104100

Ionizer Duct Assembly (includes ionizer & brush)

6

4670700

Brush

7

4401510

Ionizer Duct Standoff, long

8

4401591

Ionizer Duct Standoff, short

9

4103940

Line Cord Assembly, 120 V

9

4104393

Line Cord Assembly, 230 V

10

4610531

Rocker Switch

11

4610758

3-Position Rotary Switch with Knob

12

4672063

Lock Knob (2 required)

13

4340509

Yoke

14

5050558

Pedestal Mount Kit

15

4104329

Foot

16

4670704

Flange

17

4670838

Flange Knob

18

4640630

Post Locking 3/8 screw

19

5050281

Filter Kit

20

4470059

Filter

21

4104294

Neon Lamp Assembly, 120 V

21

4104392

Neon Lamp Assembly, 230 V

Summary of Contents for Aerostat Sentry 4003000

Page 1: ...AEROSTAT SENTRY 5100600 Rev H Aerostat Sentry Ionizing Blower INSTALLATION AND OPERATING INSTRUCTIONS...

Page 2: ...AEROSTAT SENTRY 5100600 Rev H TABLE OF CONTENTS 1 DESCRIPTION 3 2 SAFETY 4 3 SPECIFICATIONS 5 4 INSTALLATION 7 5 OPERATION 8 6 MAINTENANCE 9 7 REPLACEMENT PARTS 10 8 WARRANTY 11...

Page 3: ...ield that injects alternating polarity ions into the airflow The shaped airflow exiting the Sentry carries these ions over a broad area for static elimination The ionizer of the Sentry features a bala...

Page 4: ...m being returned should be shipped prepaid and packed to provide adequate protection 2 SAFETY NOTE Statements identified with a NOTE indicate precautions necessary to avoid potential equipment failure...

Page 5: ...elocity Fan Speed 1 ft 2 ft 3 ft 4 ft Low 600 300 180 150 Medium 800 400 220 180 High 1000 500 250 200 Velocity in FPM measured at centerline of air stream Air Flow characteristics 3 x 6 Area Coverage...

Page 6: ...t discharge time Fan Speed High 1 ft 2 ft 3 ft 4 ft 4 5 6 8 1 ft 1 5 2 5 4 5 5 Center Line 4 5 6 8 1 ft Fan Speed Medium 6 7 9 11 1 ft 1 7 3 5 5 7 Center Line 6 7 9 11 1 ft Fan Speed Low 8 9 10 12 1 f...

Page 7: ...ration Plug the unit into a standard 2 terminal double grounded receptacle To set the unit up in a bench stand configuration secure the feet to the mounting yoke 1 Place the feet on a table top with t...

Page 8: ...he Sentry produces an ionized air stream that covers a large area uniformly The time required to neutralize a static charge on an item in this area depends on many factors Two important factors are di...

Page 9: ...ers 1 Grasp the emitter cleaner between thumb and forefinger 2 Sweep back and forth across the ionized air outlet Recommended frequency of cleaning is once a week The ionized air outlet should remain...

Page 10: ...and again approach the surface with the tape If it has been neutralized it will not attract NOTE When performing this procedure do not use a plastic surface such as acrylic as the surface itself may b...

Page 11: ...h 6 4670700 Brush 7 4401510 Ionizer Duct Standoff long 8 4401591 Ionizer Duct Standoff short 9 4103940 Line Cord Assembly 120 V 9 4104393 Line Cord Assembly 230 V 10 4610531 Rocker Switch 11 4610758 3...

Page 12: ...any goods for any reason contact Simco Ion Customer Service at 215 822 6401 for a Return Authorization Number This number must accompany all returned items This warranty does not apply when the equip...