Simaudio Moon 340i Neo D2PX Owner'S Manual Download Page 4

340i 

Nēo

 

Series

 

 

 

 

Important Safety Instructions 

(cont’d)

 

 

The lightning flash with the arrowhead symbol, within an equilateral triangle, is 
intended to alert the user to the presence of uninsulated “dangerous voltage” within 
the product’s enclosure that may be of sufficient magnitude to constitute a risk of 
electric shock to persons.  

 

The exclamation point within an equilateral triangle is intended to alert the user to the 
presence of important operating and maintenance (servicing) instructions in the 
literature accompanying the appliance. 

 

Marking by the “CE” symbol (shown left) indicates compliance of this device with the 
EMC  (Electromagnetic Compatibility) and LVD (Low Voltage Directive) standards of the 
European Community

 

 

Please read all instructions and precautions carefully and 
completely before operating your Nēo

 

340i  Integrated Amplifier. 

 

1.

 

ALWAYS

 disconnect your entire system from 

the AC mains before connecting or 
disconnecting any cables, or when cleaning any 
component. To completely disconnect this 
apparatus from the AC mains, disconnect the 
power supply cord plug from the AC receptacle. 

2.

 

The 

Nēo

 340i must be terminated with a three-

conductor AC mains power cord which includes 
an earth ground connection. To prevent shock 
hazard, all three connections must 

ALWAYS

 be 

used. Connect the 

Nēo

 

340i only to an AC 

source of the proper voltage; Both the shipping 
box and rear panel serial number label will 
indicate the correct voltage. Use of any other 
voltage will likely damage the unit and void the 
warranty 

3.

 

AC extension cords are 

NOT

 recommended for 

use with this product. The mains plug of the 
power supply cord  shall remain readily 
accessible. 

4.

 

NEVER

 use flammable or combustible 

chemicals for cleaning audio components. 

5.

 

NEVER

 operate the 

Nēo

 

340i with any covers 

removed. There are no user-serviceable parts 
inside. An open unit, especially if it is still 
connected to an AC source, presents a 
potentially lethal shock hazard. Refer all 
questions to authorized service personnel only. 

 

6.

 

NEVER

 wet the inside of the 

Nēo

 

340i with any 

liquid. If a liquid substance does enter your 

Nēo

 

340i, immediately disconnect it from the AC 
mains and take it to your MOON dealer for a 
complete check-up. 

7.

 

NEVER

 spill or pour liquids directly onto the 

Nēo

 

340i. 

8.

 

NEVER

 block air flow through ventilation slots 

or heatsinks. 

9.

 

NEVER

 bypass any fuse. 

10.

 

NEVER

 replace any fuse with a value or type 

other than those specified 

11.

 

NEVER

 attempt to repair the 

Nēo

 

340i. If a 

problem occurs contact your MOON dealer. 

12.

 

NEVER

 expose the 

Nēo

 

340i to extremely high 

or low temperatures. 

13.

 

NEVER

 operate the 

Nēo

 

340i in an explosive 

atmosphere. 

14.

 

ALWAYS

 keep electrical equipment out of 

reach of children. 

15.

 

ALWAYS

 unplug sensitive electronic 

equipment during lightning storms. 

16.

 

WARNING:

 Do not expose batteries or battery 

pack to excessive heat such as sunshine, or fire 
or the like.  

 

Summary of Contents for Moon 340i Neo D2PX

Page 1: ...Integrated Amplifier Owner s Manual 340i Series...

Page 2: ...340i N o Series...

Page 3: ...or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Unplug mains cord during transportation 11 Only use attachments and accessories specified by...

Page 4: ...roper voltage Both the shipping box and rear panel serial number label will indicate the correct voltage Use of any other voltage will likely damage the unit and void the warranty 3 AC extension cords...

Page 5: ...el Controls 8 Optional Digital Inputs 9 Optional Phono Section 10 Balanced Inputs 11 Rear Panel Connections 12 SimLink 13 Operating the N o 340i 13 Remote Control Operation 14 Specifications 16 www si...

Page 6: ...rent version of this manual is available on our official website at http www simaudio com Your N o 340i Integrated Amplifier incorporates many significant design features to achieve its world class le...

Page 7: ...requires reasonable ventilation to maintain an optimum and consistent operating temperature especially since it will radiate heat when driven hard Consequently it should be placed in a location with...

Page 8: ...tially scroll either forward or backward through all of the available inputs Depending on the installed options the order of the inputs is as follows going forward Basic Unit CD A1 A2 and A3 With all...

Page 9: ...al Digital Inputs The Digital Input option includes four 4 separate inputs D1 uses an optical Toslink connector D2 and D3 use S PDIF on an female RCA connector and D4 uses a type B USB connector The D...

Page 10: ...capacitance and resisitance loading as well as gain level This flexibility allows you to optimize the 340i for a wide variety of MC and MM cartridges Circuit Board Layout Figure 3 N o 340i Optional Ph...

Page 11: ...is recommended that you leave the jumpers inserted in the factory default setting of 100pF Conversely if you re using a MC cartridge you should use the 0pF jumper settings by simply inserting the supp...

Page 12: ...a balanced signal For N o 340i s equipped with the digital input option you will find 4 digital inputs labeled D1 D2 D3 and D4 The D1 input is on an optical Toslink connector both the D2 and D3 inputs...

Page 13: ...splay begins to flash on and off The connection rules for the SimLink are very basic You must always connect the supplied cable between one component s SimLink Out jack and another component s SimLink...

Page 14: ...front panel display on and off The 2 buttons labelled INPUT allow you to sequentially scroll either backwards or forwards through all six 6 available inputs For example to switch from the CD to the VI...

Page 15: ...h the 340i automatically switching to the MiND assigned input as described previously in the SimLink section To shut down the system press Off for this ZONE in the MiND app Figure 7 Remote Operation w...

Page 16: ...olar Output Power 8 100 Watts per channel Output Power 4 200 Watts per channel Gain 37dB Signal to noise Ratio 110dB full power Frequency Response 2Hz 90kHz 0 3 0dB Crosstalk 1kHz 88dB Intermodulation...

Page 17: ...ilter ESS9018K2M DSD Data Rates 2 8224MHz Double 5 6448MHz Quadruple 11 2896 DSD Sample Rates DSD 64 DSD 128 DSD256 via USB only PCM Bit depth range 16 32 bits 32 bit via USB only PCM Sampling Frequen...

Page 18: ...340i N o Series 18...

Reviews: