Simaudio Moon 340i Neo D2PX Owner'S Manual Download Page 3

Owner’s Manual 

 

 

 

Important Safety Instructions

 

 

1.  Read these instructions. 

2.  Keep these instructions. 

3.  Heed all warnings. 

4.  Follow all instructions. 

5.  Do not use this apparatus near water. 

6.  Clean only with a dry cloth. 

7.  Do not block ventilation openings. Install in 

accordance with the manufacturer’s instructions. 

8.  Do not install near any heat sources such as 

radiators, heat registers, stoves or another 
apparatus that produces heat. 

9.  Do not defeat the safety purpose of the polarized or 

grounding type plug. A polarized plug has two 
blades with one wider than the other. A grounding-
type plug has two blades and a third grounding 
prong. The wide blade or the third prong is 
provided for safety. If the provided plug does not fit 
into the outlet, consult an electrician for 
replacement of the obsolete outlet. 

 

10.  Protect the power cord from being walked on or 

pinched, particularly at plugs, convenience 

receptacles, and the point where they exit from the 
apparatus. Unplug mains cord during 
transportation. 

11.

 

Only use attachments and accessories specified by 
the manufacturer. 

12.

 

Use only with the cart, stand, tripod, bracket, or 

table specified by the manufacturer 
or sold with the apparatus. When a 
cart is used, use caution when 

moving the cart/apparatus combination to avoid 
injury from tip over. 

13.

 

Unplug this apparatus during lightning storms or 
when unused for long periods of time. 

14.

 

Refer all servicing to qualified service personnel. 
Servicing is required when the apparatus has been 
damaged in any way, such as when the power cord 
or plug has been damaged; liquid has been spilled 
or objects have fallen into the apparatus; or the 
apparatus has been exposed to rain or moisture, 
does not operate normally, or has been dropped. 

15.

 

No naked flame sources, such as candles, should be 
placed on the apparatus. 

 

 
 

WARNING:  

TO  REDUCE  THE  RISK  OF  FIRE  OR  ELECTRIC  SHOCK,  DO  NOT 
EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. 

 
 

 

 

Summary of Contents for Moon 340i Neo D2PX

Page 1: ...Integrated Amplifier Owner s Manual 340i Series...

Page 2: ...340i N o Series...

Page 3: ...or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Unplug mains cord during transportation 11 Only use attachments and accessories specified by...

Page 4: ...roper voltage Both the shipping box and rear panel serial number label will indicate the correct voltage Use of any other voltage will likely damage the unit and void the warranty 3 AC extension cords...

Page 5: ...el Controls 8 Optional Digital Inputs 9 Optional Phono Section 10 Balanced Inputs 11 Rear Panel Connections 12 SimLink 13 Operating the N o 340i 13 Remote Control Operation 14 Specifications 16 www si...

Page 6: ...rent version of this manual is available on our official website at http www simaudio com Your N o 340i Integrated Amplifier incorporates many significant design features to achieve its world class le...

Page 7: ...requires reasonable ventilation to maintain an optimum and consistent operating temperature especially since it will radiate heat when driven hard Consequently it should be placed in a location with...

Page 8: ...tially scroll either forward or backward through all of the available inputs Depending on the installed options the order of the inputs is as follows going forward Basic Unit CD A1 A2 and A3 With all...

Page 9: ...al Digital Inputs The Digital Input option includes four 4 separate inputs D1 uses an optical Toslink connector D2 and D3 use S PDIF on an female RCA connector and D4 uses a type B USB connector The D...

Page 10: ...capacitance and resisitance loading as well as gain level This flexibility allows you to optimize the 340i for a wide variety of MC and MM cartridges Circuit Board Layout Figure 3 N o 340i Optional Ph...

Page 11: ...is recommended that you leave the jumpers inserted in the factory default setting of 100pF Conversely if you re using a MC cartridge you should use the 0pF jumper settings by simply inserting the supp...

Page 12: ...a balanced signal For N o 340i s equipped with the digital input option you will find 4 digital inputs labeled D1 D2 D3 and D4 The D1 input is on an optical Toslink connector both the D2 and D3 inputs...

Page 13: ...splay begins to flash on and off The connection rules for the SimLink are very basic You must always connect the supplied cable between one component s SimLink Out jack and another component s SimLink...

Page 14: ...front panel display on and off The 2 buttons labelled INPUT allow you to sequentially scroll either backwards or forwards through all six 6 available inputs For example to switch from the CD to the VI...

Page 15: ...h the 340i automatically switching to the MiND assigned input as described previously in the SimLink section To shut down the system press Off for this ZONE in the MiND app Figure 7 Remote Operation w...

Page 16: ...olar Output Power 8 100 Watts per channel Output Power 4 200 Watts per channel Gain 37dB Signal to noise Ratio 110dB full power Frequency Response 2Hz 90kHz 0 3 0dB Crosstalk 1kHz 88dB Intermodulation...

Page 17: ...ilter ESS9018K2M DSD Data Rates 2 8224MHz Double 5 6448MHz Quadruple 11 2896 DSD Sample Rates DSD 64 DSD 128 DSD256 via USB only PCM Bit depth range 16 32 bits 32 bit via USB only PCM Sampling Frequen...

Page 18: ...340i N o Series 18...