cavity one or two liters of clean potable water with
the antibacteria solution P/N 26400002 to rinse
and sanitize the molds and the spray system.
If necessary remove the spary bar and nozzles to
clean them separately then refit them.
9.
Set back the master switch to ON. The
water pump is again in operation to circulate the
water and the antibacterial solution in order to
rinse the entire water system.
Switch OFF the unit after approx. 10 minutes and
flush out the rinsing water from the sump reservoir.
10. To rotate the timer so that the microswitches
reach the beginning of the defrost cycle (low part
of the cam) give power to the unit by the master
switch.
By doing so are energized the water pump and
the water inlet valve. In this way the incaming
water flow away to fill up the water tank.
11. When the water tank is filled up (water
flowing out from the drain) put the compressor
switch on I ON position to restart the machine in
the automatic mode.
12. Re-fit the evaporator cover and the unit
service panels.
13. At completion of the freezing and harvest
cycle make sure of proper texture and clearness
of the ice cubes and that, they do not have any
acid taste.
ATTENTION. In case the ice cubes are
cloudy, white and have an acid taste, melt
them immediately by pouring on them
some warm water.
This to prevent somebody from using
them.
14. Wipe clean and rinse the inner surfaces of
the storage bin.
REMEMBER. To prevent the accumulation
of undesirable bacteria it is necessary to
sanitize the interior of the storage bin with
an anti-algae disinfectant solution every
week.
Page 13