Sima ATA 400 RE-BAR 25 User Manual Download Page 5

 36  · 

simasa.com

 

ƒ

The RE-BAR tier starts itself without be-

ing activated.

 

ƒ

Do not use the RE-BAR tier without cor-

recting the fault. 

 

ƒ

If it is not possible to correct it, contact 

your dealer.

4.1.14. Do not make any modifications to 

the RE-BAR tier.

Modifying the RE-BAR tier does not only 

reduce the function of it, but also the level 

of security. Do not make any modifications 

to the RE-BAR tier.

4.1.15. Make sure that the RE-BAR tier is 

in good condition.

To maintain the functionality and the quality 

from the work of the RE-BAR tier, maintain 

it properly and make sure that it is being 

serviced on a regular basis. Remember to 

keep the handle free of oil and dirt.

4.1.16. Use only approved batteries.

Use only the approved type of battery LI-

300 for this RE-BAR tier. If using another 

power source, for example another type 

of battery, dry cell battery or a car battery, 

the machine can break down or burst into 

flames. 

4.1.17. Charge the batteries before use.

A new battery or a battery which has not 

been used for a long period of time, may be 

discharged and has to be fully recharged 

before use.

4.2. Precautions in connection 

with battery charging, chargers 

and batteries.

4.2.1. Use only approved charger.

Use only the approved charger which 

comes with the RE-BAR tier and batteries. 

The batteries cannot be recharged with 

other chargers – this may cause damage, 

overheating or fire. 

4.2.2. Recharge the batteries with the 

correct voltage.

Make sure that the charger is connected 

to an ordinary 100-240V outtake. Using 

another voltage than 100-240V will cause 

a malfunction and/or overheating, causing 

damage to the battery and charger. 

4.3.3. Never use a booster-type trans-

former.

4.2.4. Never charge the battery in a wet 

or damp environment.

Charging in these conditions may cause an 

electric shock or short circuit. 

4.2.5. Do not touch the plug or charger 

with a wet hand or glove.

You will risk injury from electric shock.

4.2.6. Do not place anything on the 

charger during use. 

The charger may become overheated and 

eventually catch fire. 

4.2.7. Make sure not to place charger 

and battery next to a heating source or 

open fire.

4.2.8. Do not place the battery near 

flammable items.

4.2.9. Charge the battery in a well venti-

lated place.

Avoid placing it in direct sunlight.

4.2.10. Charge the battery at a tempera-

ture b5° and +40° Celsius.

4.2.11. Leave the charger to rest be-

tween charges.

4.2.12. Keep the charger’s connectors 

clean.

All objects on the connectors can cause 

electric chock or malfunction. Use the 

charger in a dust- and dirt-free environ-

ment.

4.2.13. Handle the charger cord care-

fully.

Do not carry the charger in the cord, and 

do not unplug it by pulling the cord. You will 

risk that the cord becomes damaged and 

will cause a malfunction. A damaged cord 

must be replaced or repaired. 

4.2.14. Put the cap on the battery con-

nectors when not in use.

This must be done to prevent a short circuit 

in the battery. 

4.2.15. Make sure that the battery con-

nectors do not touch each other.

A short circuit between the connectors will 

overheat and damage the batteries. 

Summary of Contents for ATA 400 RE-BAR 25

Page 1: ......

Page 2: ...Guide Wire Guide C Label Reel Stay Battery Head Cover Locking piece LED 1 LED 2 LED 2 ON Power is on LED 1 OFF Battery is not connected LED 1 ON Battery is charging LED 1 2 ON Battery is fully charged...

Page 3: ...AR tier will not work properly 4 2 Re cycling of Li Ion batteries The batteries for the TJEP RE BAR tier are Li Ion It may be illegal to dispose of the battery through the ordinary waste system Your l...

Page 4: ...heck the parts of the RE BAR tier before inserting the battery Check that all screws are tightened prop erly Improper tightening of screws can result in an accident or breakage If parts are missing or...

Page 5: ...ure that the charger is connected to an ordinary 100 240V outtake Using another voltage than 100 240V will cause a malfunction and or overheating causing damage to the battery and charger 4 3 3 Never...

Page 6: ...e feeding gears and all the way into the machine arm max 70 mm If the window is dirty and it is difficult to determine the position of the wire guide C clean the inside of window with a soft cloth 5 1...

Page 7: ...ion activate the trigger lock and remove the battery Battery Battery x Trigger lock 5 5 2 Push the release lever until it is caught by the release stopper 5 5 3 Remove the wire coil 5 5 4 Push the ree...

Page 8: ...he machine and causing problems This can be done with an air blow gun 9 Storage The RE BAR tier must not be stored in cold conditions It should be kept at approx 20 C When the machine is not in use it...

Page 9: ...plate Pos 61 and Route PWB unit Pos 62 Or check the wire K connection Remove the foreign sub stance between Magnetic plate Pos 61 and Route PWB unit Pos 62 Or replace a new connecting wire K Four sho...

Page 10: ...or is burned Check the wire A and B con nection Reconnect or replace the wire A and B Or replace a new twisting motor Binding power is week No sound emitted Reinforcing bars is not of designated size...

Reviews: