SIM-04
DIGITAL DUAL DETECTOR
PIR AND MICROWAVE
INSTALLATION INSTRUCTIONS
P/N 7106762 Rev A
Wide Angle Lens
AVOID THE FOLLOWING LOCATIONS:
Facing direct sunlight.
Facing areas that may change temperature rapidly.
Areas where there are air ducts or substantial
airflows.
Avoid screen, curtain that may block detection area.
Do not install outdoors.
SPECIFICATION
Detection Method
PIR element &
microwave
pulse
Doppler
Power Input
8.2 to 16 Vdc
Current Draw
Active : 25.5 mA
Standby: 16.5 mA
Temperature
Compensation YES
Alarm Period
2 +/- 1 sec
Alarm Output
N.C 28Vdc 0.1 A
with
10 Ohm series
protection
resistors
Tamper Switch
N.C 28Vdc 0.1A
with10 Ohm
series protection
resistor - open
when cover is
removed
Warm Up Period
1 min
LED Indications
Yellow blinking during warm up period and self
testing
Red LED: ON during alarm
Green LED: PIR CHANNEL
Yellow LED: MW CHANNEL
Dimensions 115mm x 61mm x
37.5mm
Weight 120g
INSTALLING THE DETECTOR
Holding
Screw
Cover
Base
WIRE REQUIREMENTS
Use #22 AWG (0.5mm) or wires with a larger
diameter. Use the following table to determine
required wire gauge (diameter) and length of wire
between the detector and the control panel.
Wire Length m 200 300 400 800
Wire Diameter mm .5 .75 1.0 1.5
Wire Length ft 800 1200 2000 3400
Wire Gauge # 22 20 18 16
PCB LAYOUT