Smart Machine Smart Decision
SIM5360_Hardware Design_V1.01
2013-11-22
25
Figure 14: Seiko XH414H-IV01E Charge-Discharge characteristic
3.2
Power on/off Time Sequence
3.2.1
Power on Sequence
SIM5360 can be powered on by POWER_ON pin, which starts normal operating mode.
POWER_ON pin is pulled up with a 200kR resistor to 1.8V in module. User can power on the SIM5360
by pulling the POWER_ON pin down for a short time. The power-on scenarios are illustrated in the
following figures.