Smart Machine Smart Decision
SIM5360_Hardware Design_V1.01
2013-11-22
55
Table 36: Absolute maximum ratings
Parameter
Min
Max
Unit
Voltage at digital pins (1.8v digital I/O)
-0.3
2.1
V
Voltage at VBAT
-0.5
6.0
V
Voltage at VRTC
2
3.25
V
Voltage at USB_VBUS
-0.5
6.0
V
Table 37: Recommended operating ratings
Parameter
Min
Typ
Max
Unit
Voltage at digital pins (1.8v digital I/O)
0
1.8
1.95
V
Voltage at VBAT
3.3
3.8
4.2
V
Voltage at VRTC
2
-
3.2
V
Voltage at USB_VBUS
3
5
5.25
V
The operating temperature and power specification is listed in the following table.
Table 38: Operating temperature
Parameter
Min
Typ
Max
Unit
Normal operation temperature
-30
25
80
℃
Extended operation temperature
-40
25
85
℃
Storage temperature
-40
25
+90
℃
Note: SIMCom recommends user to install a heat sink on the module shielding case if SIM5360 operates in WCDMA
band.
5.2
Operating Mode
The following table summarizes the various operating modes, each operating modes will be referred to in
the following chapters.
5.2.1
Operating Modes Overview
Table 39: Operating Modes Overview
Mode
Function