background image

09

8. PRODUCT SAFETY

9. POWER GOOD SIGNAL

8.1 Safety Requirement

6.3.1 Sweep and resonance search for each of X,Y,Z, axis at the sweep.

TUV, UL/c-UL,CB

8.2 Leakage Current

The AC leakage current is less than 3.5mA when the power supply connect to 
253Vac/50Hz .

8.3 Insulation Resistance

The insulation resistance should be not less than 30M ohm after applying of 
500VDC for 1 minute.

8.4 Dielectric Voltage Withstand

The power supply shall withstand for 1 minute without breakdown the application 
of a 60Hz 1500V AC voltage applied between both input line and chassis (20mA 
DC cut-off current). Main transformer shall similarly withstand 3000Vac applied 
between both primary and secondary windings for a minimum of one minute.

A TTL compatible signal for the purpose of initiating an orderly start-up procedure 
under normal input operating conditions. During power up, this signal is asserted 
( low ) until +5V is under regulation and AC reaches min. line specification range. 
After all voltage are going appropriate level, the system may have a turn on delay 
of 100mS, but no greater than 500mS. During power off the signal should go to low 
level 5V is out of regulation. The low level is 0 to 0.8V and high level is 4.75 
to 5.25V. The " Power Good "signal can drive up to 6 standard TTL loads.

7. CONDUCTED EMI 

FCC, CE

6.3 Vibration and Shock

Frequency

5-55-10 Hz

Amplitude

0.35 mm

Duration

30 minutes

10

Strider Essential Series  

T1 : Turn on time ( 2 sec. Max.)   
T2 : Rise time (   20mS Max.)
T3 : Power good turn on delay time ( 100 < T3 < 500 mS )
T4 : Switch on time (0.5 sec. Max.)
T5 : Power good turn off delay time ( 1.0 mS Min.) PS-ON/OFF
T6 : Power hold-on time ( 16 mS Min.)
Power on-off cycle : 

<

=

When the power supply is turned off for a minimum of 2.0 sec. and turn on again, 
the power good signal will be asserted.

The MTBF of the power should be 100,000 hours min.

Applying 220Vac for 230V model.

Time Diagram

10. MTBF

The product shall meet requirement for EN61000-3-2 & EN61000-3-3 :1995 standard 
of class D, test at 230Vac 50Hz.

12. Harmonics

11. Burn-In

11.1 Input Voltage

Applying 75% loads for the power supply in 45 (+/-5)  C chamber for 4 hours.

11.2 Test Condition

o

Summary of Contents for ST70F-ES

Page 1: ...temperature Class leading single 12V rail Multiple protection circuitry Silent running 120mm fan with 18dBA PCI E 8pin and PCI E 6pin connector support ATX 12V 2 3 support Active PFC circuitry Power...

Page 2: ...uency 2 3 Max Input AC Current 2 4 Inrush Current 2 2 1 ST70F ES 2 2 2 ST60F ES Strider Essential Series Nominal Frequency 50 60 Hz Frequency Variation Range 47 Hz to 63 Hz Nominal Frequency 50 60 Hz...

Page 3: ...rider Essential Series Maximum continuous total DC output power should not exceed 600W Maximum continuous combined load on 3 3VDC and 5VDC outputs shall not exceed 150W Maximum combined load on 12V ra...

Page 4: ...2 5 A 12V 0 05 A 0 15 A 0 3 A 5V 3 24 A 8 09 A 16 2 A 3 3V 3 24 A 8 09 A 16 2 A 12V 7 52A 18 8 A 37 6 A 06 3 7 PG OK PG OK is a power good signal and should be asserted high by power supply to indica...

Page 5: ...will latch off 5VSB will auto recovery 4 2 4 Short Circuit Protection 08 Strider Essential Series 5 START STABILITY 6 ENVIRONMENTS 5 1 No Load Start When power is applied to ST70F ES ST60F ES with no...

Page 6: ...range After all voltage are going appropriate level the system may have a turn on delay of 100mS but no greater than 500mS During power off the signal should go to low level before 5V is out of regula...

Page 7: ...than 0 9 at 230V 50Hz Max load 13 Power Factor 150 mm W 86 mm H 140mm D 14 MECHANICAL REQUIREMENTS 14 1 Physical Dimension 14 2 Connectors 12 Strider Essential Series 4PIN peripheral connector HDD 4P...

Reviews: