The power supply can be used electronic circuit to limit the output current 
against exceeding 60% of surge output power or protected against excessive 
power delivery since short circuit of any output or over total power at high line.

4.2.3 Over Power Protection

3.8 3.3V Sense

A default 3.3V sense line should be implemented pin 13 of the connector.

Output

+5V

+12V

+3.3V
-12V

+5VS

Capacitive load (uF)

6,000

8,000

6,000
350

350

3.9 Capacitive Load

4.1 Input Protection

4. PROTECTION

The power supply should be able to power up and operate normally with the 
following capacitances simultaneously present on the DC outputs.

In primary circuit of the power supply, a protected fuse is inserted. Only internal 
fault of the power supply will cause the fuse blown. Any overload or short circuit 
at DC output will keep from fuse brown or fire hazard.

The +5V/+12V/+3.3V DC output are protected against the under voltage condition. 
range value can't be exceed 3.3~3.7V at 5V terminal and 8.5~9.5V at 12V, 2.0~2.4V 
at 3.3V.

4.2 Output Protection

4.2.1 Under voltage protection

The +5V/+12V/+3.3V DC output are protected against the over voltage condition. 
Maximum value can't be over 6.5V at 5V terminal and 15.5V at 12V, 4.3V at 3.3V.

4.2.2 Over Voltage Protection

Short circuit placed on +5V,+12V,+3.3V,-12V will latch off. +5VSB will auto-recovery.

4.2.4 Short Circuit Protection

08

Strider Essential Series  

5. START STABILITY

6. ENVIRONMENTS

5.1 No Load Start

When power is applied to ST70F-ES & ST60F-ES with no load connected or 
under minimum load connected, neither damage to power supply nor hazards 
to users will occur.

5.2 Cold Start

6.1 Temperature and Humidity

6.2 Altitude

6.1.1 Operating

The power supply shall operate properly when first applied at normal input 
voltage and or so maximum load after 4 hours storage in 0 C environment.

4.2.6 Over-Temperature Protection 

This power supply includes an over-temperature protection sensor, which can trip 
and shut down the power supply at 110 C

The power supply can operate normally at any altitude between 0 to 10000 feet.

Temperature 

 

0 to 40 C  

Relative Humidity 

20 to 90 %

o

6.1.2 Storage

Temperature 

 

-40 to 70 C

Relative Humidity 

20 to 95 % noncondensing

o

o

o

Current protection should be designed to limit the current to operate within safe 
operating conditions. Over current protection schemes where only the voltage 
output that experiences the over current event is shut off may be adequate to 
maintain safe operation of the power supply and the system; however, damage 
to the motherboard or other system components may occur. The recommended 
over current protection scheme is for the power supply to latch into the shutdown 
state. The setting of over current protection for each output rail is as following.

4.2.5 Over-Current Protection

Summary of Contents for ST70F-ES

Page 1: ...temperature Class leading single 12V rail Multiple protection circuitry Silent running 120mm fan with 18dBA PCI E 8pin and PCI E 6pin connector support ATX 12V 2 3 support Active PFC circuitry Power...

Page 2: ...uency 2 3 Max Input AC Current 2 4 Inrush Current 2 2 1 ST70F ES 2 2 2 ST60F ES Strider Essential Series Nominal Frequency 50 60 Hz Frequency Variation Range 47 Hz to 63 Hz Nominal Frequency 50 60 Hz...

Page 3: ...rider Essential Series Maximum continuous total DC output power should not exceed 600W Maximum continuous combined load on 3 3VDC and 5VDC outputs shall not exceed 150W Maximum combined load on 12V ra...

Page 4: ...2 5 A 12V 0 05 A 0 15 A 0 3 A 5V 3 24 A 8 09 A 16 2 A 3 3V 3 24 A 8 09 A 16 2 A 12V 7 52A 18 8 A 37 6 A 06 3 7 PG OK PG OK is a power good signal and should be asserted high by power supply to indica...

Page 5: ...will latch off 5VSB will auto recovery 4 2 4 Short Circuit Protection 08 Strider Essential Series 5 START STABILITY 6 ENVIRONMENTS 5 1 No Load Start When power is applied to ST70F ES ST60F ES with no...

Page 6: ...range After all voltage are going appropriate level the system may have a turn on delay of 100mS but no greater than 500mS During power off the signal should go to low level before 5V is out of regula...

Page 7: ...than 0 9 at 230V 50Hz Max load 13 Power Factor 150 mm W 86 mm H 140mm D 14 MECHANICAL REQUIREMENTS 14 1 Physical Dimension 14 2 Connectors 12 Strider Essential Series 4PIN peripheral connector HDD 4P...