06
(1)T3: Power good signal turn on delay time (100ms~500ms)
(2)T2: Rise time(0.1~20ms)
(3)T6: Hold up time (75%Load 16ms)
When the power loss its input power, it shall maintain 16ms in regulation limit at normal
input voltage and 75% full load (AC:115V/60Hz or 230V/50Hz)
The power supply designed to meet UL 60950.
4.2 Hold up time
5.1 Operation
5. ENVIRONMENT
6.1 Underwriters Laboratory (UL) recognition.
6. SAFETY
7.1 ELECTROSTATIC DISCHARGE (ESD) - IEC 61000 – 4 - 2
:
2008
7.2 ELECTRICAL FAST TRANSIENT / BURST ( EFT/B) – IEC 61000 – 4 - 4
:
2012
7.3 SURGE – IEC 61000 – 4 - 5
:
2005
7.4 POWER FREQUENCY MAGNETIC FIELD – IEC 61000 – 4 - 8
:
2009
7.5 VOLTAGE DIPS – IEC 61000 – 4 - 11
:
2004
7.6 RADIATED SUSCEPTIBILTY – IEC 61000 – 4 – 3
:
2006+A1
:
2007+A2
:
2010
7.7 CONDUCTED SUSCEPTIBILTY – IEC 61000 – 4 - 6
:
2008
7.8 VOLTAGE FLUCTATION - EN 61000 – 3 – 3
:
2008
7. ELECTROMAGNETIC COMPATIBILITY (EMC)
Temperature
Relative Humidity
0 to 40C
10 to 90%, non-condensing
o
5.2 Shipping and Storage
Temperature
Relative Humidity
-20 to 90C
5 to 95%, non-condensing
o
5.3 Altitude
Operating
Storage
10,000FT max
50,000FT max