background image

CI ICA I

SilverStone Strider Titanium

ST80F-TI
ST70F-TI
ST60F-TI

ATX12V / EPS 12V Switching Power Supply

With Active PFC

80Plus Titanium

PS/2

0

1.1 AC input requirements

The input voltage, current, and frequency requirements for continuous operation are stated below.

Table 1 AC Input Line Requirements

Power factor correction (PF)>0.90 at full load.

The power supply must meet inrush requirements for any rated AC voltage, during turn on at any phase 

of AC voltage, during a single cycle AC dropout condition, during repetitive ON/OFF cycling of AC, and 

over the specified temperature range (Top). The peak inrush current shall be less than the ratings of its 

critical components (including input fuse, bulk rectifiers, and surge limiting device).

This specification describes the requirements of 600,700,800 Watts switching power supply with an stretch 
ATX form-factor and EPS 12V, +5V standby voltage ,remote on/off control, full range line input capability 
and forced air cooling characteristics.

1. AC INPUT

Parameter

Vin( Full range )

Vin Frequency

Iin(600W)
Iin(700W)
Iin(800W)

Min.

90
47

-
-
-

Nom.

100---240

60-----50

 9-----4.5

10------5

11--- 5.5

Max.

264

63

-
-
-

Unit

VACrms

Hz

Arms
Arms
Arms

Summary of Contents for ST60F-TI

Page 1: ...ciency with 80 PLUS Titanium certification Compact design with a depth of 150mm for easy integration 100 modular cables 24 7 continuous power output with 40C operating temperature Class leading single...

Page 2: ......

Page 3: ...e keep this manual for future reference when upgrading or performing maintenance on your system A copy of this manual can also be downloaded from our website at Installation and system optimization gu...

Page 4: ...le cycle AC dropout condition during repetitive ON OFF cycling of AC and over the specified temperature range Top The peak inrush current shall be less than the ratings of its critical components incl...

Page 5: ...OUTPUT Parameter 3 3V 5V 12V 12V 5VSB Range 3 3 3 10 5 Min 3 20 4 85 11 64 13 20 4 75 Nom 3 30 5 00 12 00 12 00 5 00 Max 3 39 5 15 12 36 10 80 5 25 Unit Volts Volts Volts Volts Volts Parameter 3 3V 5...

Page 6: ...all outputs The ripple voltage of the outputs shall be measured at the pins of the output connector when terminated in the load impedance specified in figure 1 Ripple and noise are measured at the co...

Page 7: ...cuit condition 3 3 Over power protection The power supply will be shutdown and latch off when output power within 110 160 of rated DC output Note Assurance machine can work at low voltage full load wo...

Page 8: ...use any damage to the power supply The power supply shall either shut down and latch off or fold back for shorting the negative rails 5VSB must be capable of being shorted indefinitely but when the sh...

Page 9: ...C DISCHARGE ESD IEC 61000 4 2 2008 7 2 ELECTRICAL FAST TRANSIENT BURST EFT B IEC 61000 4 4 2012 7 3 SURGE IEC 61000 4 5 2005 7 4 POWER FREQUENCY MAGNETIC FIELD IEC 61000 4 8 2009 7 5 VOLTAGE DIPS IEC...

Page 10: ...61000 3 2 Class D and the Guidelines for the Suppression of Harmonics in Appliances and General Use Equipment Class D for harmonic line current content at full rated power The demonstrated MTBF shall...

Page 11: ......

Page 12: ...G11226000...

Reviews: