2.6 Remote ON/OFF control

3. PROTECTION

3.1 Over current protection

3.2 Over Temperature Protection

The power supply shall have current limit to prevent the +3.3V,+5V,and +12V outputs from 
exceeding the values shown in the following Table. If the current limits are exceeded the 
power supply shall shutdown and latch off.

The power supply will be protected against over temperature conditions caused by loss of  
fan cooling or excessive ambient temperature. In an OTP condition the PSU will shutdown. 
When the power supply temperature drops to within specifide limits, the power supply shall 
restore power automatically. The OTP circuit temperature drops to within specifide limits, 
the power supply shall restore power automatically. The OTP circuit condition.

3.3 Over-power protection

The power supply will be shutdown and latch off when output power within 110~160% of 
rated DC output.
Note: Assurance machine can work at low voltage,full load won't damage machine.

3.4 Under voltage protection.

In an under voltage fault occurs, the supply will latch all DC outputs into a shutdown state 
when +12V,+5V & +3.3V outputs under 85% of it's maximum value.

ST60F-TI

When the logic level "PS-ON" is low, the DC outputs are to be enabled.
When the logic level is high or open collector, the DC outputs are to be disabled.

Voltage

+12V

+5V

+3.3V

Over Current Limit (Iout limit) 

49A  minimum;   75A  maximum
22A  minimum;   45A  maximum
22A  minimum;   45A  maximum

ST70F-TI

Voltage

+12V

+5V

+3.3V

Over Current Limit (Iout limit) 

58A  minimum;   87A  maximum
24A  minimum;   45A  maximum
24A  minimum;   45A  maximum

ST80F-TI

Voltage

+12V

+5V

+3.3V

Over Current Limit (Iout limit) 

66A  minimum;   95A  maximum
24A  minimum;   45A  maximum
24A  minimum;   45A  maximum

Summary of Contents for ST60F-TI

Page 1: ...ciency with 80 PLUS Titanium certification Compact design with a depth of 150mm for easy integration 100 modular cables 24 7 continuous power output with 40C operating temperature Class leading single...

Page 2: ......

Page 3: ...e keep this manual for future reference when upgrading or performing maintenance on your system A copy of this manual can also be downloaded from our website at Installation and system optimization gu...

Page 4: ...le cycle AC dropout condition during repetitive ON OFF cycling of AC and over the specified temperature range Top The peak inrush current shall be less than the ratings of its critical components incl...

Page 5: ...OUTPUT Parameter 3 3V 5V 12V 12V 5VSB Range 3 3 3 10 5 Min 3 20 4 85 11 64 13 20 4 75 Nom 3 30 5 00 12 00 12 00 5 00 Max 3 39 5 15 12 36 10 80 5 25 Unit Volts Volts Volts Volts Volts Parameter 3 3V 5...

Page 6: ...all outputs The ripple voltage of the outputs shall be measured at the pins of the output connector when terminated in the load impedance specified in figure 1 Ripple and noise are measured at the co...

Page 7: ...cuit condition 3 3 Over power protection The power supply will be shutdown and latch off when output power within 110 160 of rated DC output Note Assurance machine can work at low voltage full load wo...

Page 8: ...use any damage to the power supply The power supply shall either shut down and latch off or fold back for shorting the negative rails 5VSB must be capable of being shorted indefinitely but when the sh...

Page 9: ...C DISCHARGE ESD IEC 61000 4 2 2008 7 2 ELECTRICAL FAST TRANSIENT BURST EFT B IEC 61000 4 4 2012 7 3 SURGE IEC 61000 4 5 2005 7 4 POWER FREQUENCY MAGNETIC FIELD IEC 61000 4 8 2009 7 5 VOLTAGE DIPS IEC...

Page 10: ...61000 3 2 Class D and the Guidelines for the Suppression of Harmonics in Appliances and General Use Equipment Class D for harmonic line current content at full rated power The demonstrated MTBF shall...

Page 11: ......

Page 12: ...G11226000...

Reviews: