Flow In Premium
02/07/2018
65
Unpacking and assembling
Assembling the device > Reducing adapter (for exhaust air fan operation with
Ø
125 mm air duct only)
7.
Place the activated charcoal filter housing (Fig.
43/1) in the prepared cutout.
Fixate the activated carbon filter housing (Fig. 43/2) inside
the prepared opening using 2 screws.
Fig. 43
1
Activated carbon filter housing
2 Connecting screw
8.
Insert the activated carbon filter (Fig. 44/2) into the
activated carbon filter housing (Fig. 44/1)
Fig. 44
1
Activated carbon filter housing
2
Activated carbon filter
9.
Establish the power supply connection for the device;
10.
Connect the cooking field power cable with ajunc
-
tion box designated for cooking ranges (Fig. 45/2) with the
data cable from the switch box (Fig. 45/3).
11.
Plug the mains cable of the hob extractor (Fig. 45/1)
into the socket (Fig. 45/5) (Fig. 45).
12.
Plug the power cord of the control box (Fig. 45/4) into
the socket (Fig. 45/5).
13.
Plug the motor connection cable from the control box
(Fig. 45/6) into the plug on the motor (Fig. 45).
14.
Complete connecting the device with the air outlet.
22.3.2 Assemble the reducing adapter (for exhaust air fan operation
with Ø 125mm air duct only)
For the exhaust air fan operation, a wall opening (possibly requir-
ing a core hole drilling) with a diameter of 150 mm is necessary.
Fig. 45: POWER SUPPLY CONNECTION