![background image](http://html1.mh-extra.com/html/silverline/as5323x01/as5323x01_user-manual_1273374034.webp)
30
used with the unit.
After completing the injector installation, check the gas
sealing with foam. Apply foam to the bottom of the injectors
for this purpose. Press on the injector with your finger so
that the gas outlet is closed and check for any bubbles on
the connection areas of the injector.
TECHNICAL INFORMATION ON GAS BURNERS
A Burner
SR
Burner
R Burner
Wok Burner
(3,3 kW)
Wok Burner
(2,5 kW)
Wok Burner
(3,8 kW)
G 30-30
mbar LPG
(0,50 mm)
G 30-30
mbar LPG
(0,65 mm)
G 30-30
mbar LPG
(0,85 mm)
G 30-30
mbar LPG
(0,89 mm)
G 30-30
mbar LPG
(0,82 mm)
G 30-30
mbar LPG
(0,98 mm)
G20
–20
mbar
NATURAL
GAS
(0,72 mm)
G20
–20
mbar
NATURAL
GAS
(0,97 mm)
G20
–20
mbar
NATURAL
GAS
(1,15 mm)
G20
– 20
mbar
NATURAL
GAS
(1,28 mm)
G20
– 20
mbar
NATURAL
GAS
(1,15 mm)
G20
– 20
mbar
NATURAL
GAS
(1,35 mm)
Note:
The burner positions on the burner table are indicated on
the burner plate.
1 Nitril/Klingerit Gasket
2 Elbow
3 LPG Hose Entrance