27
When the power cable is damaged this cable should be
changed with a special cable to be supplied by a special cable
agency or the authorized service dealer.
No reducer, adapter, and switch should be used for electrical
connection since it will cause excessive heat and fire.
Plug the electric cable to a grounded wall socket. The
manufacturer hereby declares that it will be released all liability
in the event of any failure in this issue.
The supply data of the electric network should be suitable with
the data on the type label of the unit.
GAS CONNECTION
These instructions are prepared for specialist personnel having
required competence, the installation of the equipment should
be suitable as per the applicable standards.
All gas related works should be conducted when the
electric connection was cut.
The value plate on the hob indicates the gas type intended to
be used for use with the hob. Connection to the main gas
course or gas type shall be realized after controlling the
adjustment as per the gas type. Connection to the main gas
source or gas cylinder shall be conducted after checking the
adjustment according to the proper gas type. If it is set properly
look at the following paragraphs:
Note that the LPG hoods should have TSE stamp and 300
mmSS (30mbar) of outlet pressure.
Natural gas pressure is 200 mmSS (20mbar). Please consult the
authorized service for conversion to natural gas or LPG.
Use only piping, gaskets or seal as per the applicable national
standards.
In some countries where conic connections are obligatory, conic
connection is provided. In such a case the conic connection part
should be connected to the unit.
Summary of Contents for AS5323X01