Transistor hFE Test

Diode Test

•   

Overload protection: 250V effective value.

•   Forward DC current: approximate 1mA.

•   Reversed DC voltage: approximate 3.0V.

Continuity

•   Overload protection: 250V effective value.

    Open circuit voltage: approximate 3.0V.

Capacitor

•   

Overload protection: 250V effective value.

Battery

PRIOR TO USE

   

Thoroughly read and understand the operating instructions.

•   Check 9v battery, if the battery voltage is less than 7v, display  

   will show '     ', the battery should be replaced at this time to    

   ensure measuring precision.

•   Pay attention to the "     " besides the input jack which shows   

   that the input voltage or current should be within the specified   

   value.

•   The range switch should be positioned to the desired 

   measurement range for measurement before operation.

OPERATING INSTRUCTIONS

Measuring DC Voltage

•   Connect the black test to COM jack and the red to VΩmA jack.

•   Set the rotary switch at the desired V     range position.

•   Connect test leads across the source or load under

   measurement.

•   You can get reading from LCD. The polarity of the red lead    

   connection will be indicated along with the voltage value. 

Note:

•   When the value scale to be measured is unknown beforehand,  

    set the range selector at the highest position.

•   When the figure '1' of '-1' is displayed, it indicates over- 

 

   range situation and the higher range has to be selected.

•   "     " means you can't input voltage higher than 600V, it's 

   possible to show higher voltage, but it may destroy the inner     

   circuit or pose a shock hazard.

•   Always exercise caution when working with electric, if in any     

   doubt seek advice from a qualified electrician.

Measuring AC Voltage

•   Connect the black test to COM jack and the red to VΩmA jack.

•   Set the rotary switch at the desired V~ range position.

•   Connect test leads across the source or load under

   measurement.

Note:

•   

When the value scale to be measured is unknown, set the    

   range selector at the highest position.

•   When only the figure '1' or '-1' is displayed, it indicates an 

   over-range situation a higher range should be selected.

•   "     " means you can't input voltage higher than 600V, it's  

 

   possible to show higher voltage, but it may destroy the inner    

   circuit or pose a shock hazard.

•   Always exercise caution when working with electric, if in any     

   doubt seek advice from a qualified electrician.

Measuring DC/AC Current

•   Connect the black test lead to COM jack and the red to the    

    VΩmA jack for a maximum 200mA current.

•   Set the rotary switch at the desired A    /A~ range position.

•   Connect test leads in series with the load under measurement.

•   The polarity of the red lead connection will be indicated along   

   with the current value.

Note:

   When the value scale to be measured is unknown, set the    

   range selector at the highest position.

•   When only the figure '1' or '-1' is displayed, it indicates an 

   over-range situation a higher range should be selected.

•   "     " means the socket mA's maximum current is 200mA and   

   10A's maximum current is 10A, over current will destroy the    

   fuse. Since 10A is not fused, the measuring time should be    

   less than 1 second to prevent precision from affecting by circuit  

    heating.

Measuring Resistance

•   

Connect the black test lead to COM jack and the red to VΩmA  

   jack.

•   Set the rotary switch at the desired Ω range position.

•   Connect test leads across the resistance under measurement.

•   You can get reading from LCD.

Note:

•   When only the figure '1' or '-1' is displayed, it indicates an 

   over-range situation a higher range should be selected.

•   For measuring resistance above 1MΩ, the meter may take a    

   few seconds to get a stable reading.

•   When the input is not connected,  i.e. at open circuit, the figure  

    '1' will be displayed for the over-range condition.

•   

When checking in-circuit resistance, be sure the circuit    

   under test has all power removed and that all capacitors    

   have been discharged fully.

•   When the value scale to be measured is unknown, set the    

   range selector at the highest position.

Transistor Testing

•   Set the rotary switch at 'hFE' position.

•   Determine whether the transistor under testing is NPN or PNP  

   and locate the emitter, base and collector leads. Insert the    

   leads into proper holes of hFE socket on the front panel.

•   Read the approximate hFE value at the testing condition of    

    base current 1b10uA and Vce 3V.

Diode Testing

•   Connect the black test lead to COM jack and the red to VΩmA,  

    jack. (The polarity of red lead '+').

•   Set the rotary switch at the F range position.

SAFETy INSTRUCTIONS

It is important to read and understand your instruction manual.  

Learn the tools application, as well as it's limitations and the 

potential hazards associated with this tool.

ADDITIONAL SAFETy INFORMATION FOR MULTIMETER

•   The meter is designed according to IEC-1010 with an 

   over-voltage category (CAT III) and pollution 2.

•   Follow all safety and operating instructions to ensure that  

 

   the meter is used safely and is kept in good operating 

   condition.

•   Safety Symbols:

   Important safety information, refer to the operating manual.

   Dangerous voltage maybe present.

•   Double insulation (Protection Class III).

•   The meter is safe only according to standard procedures  

 

   when used in conjunction with the supplied test leads. Replace  

    damaged test leads only with the same model or same 

   electric specifications.

•   Do not use the meter before the cover is in place to avoid  

 

   risk of electric shock.

•   The range switch should be in the right position for testing.

•   To avoid electric shock and damaging the instrument, the input  

    signals should not exceed the specified limits.

•   When measuring switched power such as TV sets, attention     

   should be paid to the possible pulses that may cause 

   destruction of the circuit.

•   Range switch position should never be changed at random    

    during measurement.

•   Caution against shock when measuring voltages higher than     

   DC 60V & AC 30V.

•   Protection fuse should be replaced only with same type and     

   specification. 

1. LCD Display: 3

1

/

2

 digits, character 16mm high

2. Back Light Button Switch: Press button to switch on the  

 

   back light, it will automatically switch off after 5 seconds. 

3. Rotary switch: use this switch to select functions and ranges.

4. V Ω mA Cx+ Input Jack

5. COM Input Jack

6. Cx- Input Jack

7. Data-hold Switch (HOLD)

 

SPECIFICATIONS

•   

Max voltage between input terminal and earth ground: CAT    

    III 600V.

•   Over-range indication: display "1" for the significant digit.

•   Automatic display if negative polarity "_".

•   Low battery indication: '      ' displayed.

•   Max LCD display: 1999 (3

1

/

2

) digits).

•   Fuse protection: F-200mA/250V (ø5x20mm).

•   Power supply: 9V battery.

•   Operating temp: 0˚C (relative humidity <85%).

•   Storage temp: 10˚C to 50˚C (relative humidity <85%).

•   Guaranteed precision temp: 23+5 ˚C (relative humidity <85%).

•   Dimensions: 143x75x32mm.

•   Weight: approx 200g (including battery).

Accuracy is specified for a period of 1 year after calibration and at 

18˚C to 28˚C (64˚F to 82˚F) with relative humidity to 75%.

DC Voltage

•   Input impedance: 10MΩ.

•   Overload protection: 250V for 200mV range, effective DC or    

   AC 600V for other ranges.

AC Voltage

•   Frequency range: 40 to 400HZ.

•   Response: average, calibrated in rms of sine wave.

DC Current

•  Overload protection: F 200mA/250V fuse.

AC Current

Resistance

   Overload protection: 250V effective value.

1

5

3

2

4

6

7

Product Familiarisation 

Digital Multimeter

Range

Resolution

Accuracy

200V

100mV

+1.2% of rdg+20 digits

600V

1V

+1.2% of rdg+20 digits

Range

Resolution

Accuracy

200uA

0.1µA

+1.0% of rdg+20 digits

200mA

0.1mA

+1.5% of rdg+20 digits

Range

Resolution

Accuracy

200uA

0.1µA

+1.8% of rdg+20 digits

200mA

0.1mA

+2.5% of rdg+20 digits

Range

Resolution

Accuracy

200Ω

0.1Ω

+1.0% of rdg+25 digits

20KΩ

10Ω

20MΩ

10KΩ

+1.0% of rdg+20 digits

+2.5% of rdg+20 digits

Range

Test Range

Test Current/Voltage

NPN & PNP

0-1000

Ib=10uA/Vce=3V

Range

Resolution

Function

1mV

Display: read approximate 

forward voltage of diode

Range

Function

Built-in buzzer will sound if resistance is 

lower than 50

Range

Resolution

Accuracy

200nF

0.1nF

+2.5% of rdg+30 digits

20uF

0.01uF

0.01uF

+2.5% of rdg+30 digits

+9.0% of rdg+40 digits

0.01uF-10-

10uF-20uF

Range

Load Resistance

Battery By Test Is Good

1.5V

36Ω

more than 33mA

9V

360Ω

12V

450Ω

more than 18mA

more than 14mA

Range

Resolution

Accuracy

200mV

0.1mV

+0.5% of rdg+17 digits

20V

10mV

600V

1V

+0.8% of rdg+18 digits

+0.8% of rdg+18 digits