Contact
For technical or repair service advice, please contact the helpline on (+44) 1935 382 222
Web:
silverlinetools.com/en-GB/Support
Address:
Powerbox
Boundary Way
Lufton Trading Estate
Yeovil, Somerset
BA22 8HZ, United Kingdom
Storage
• When storing the heater, ensure that it has totally cooled down and is completely dry.
• Cover the heater with a plastic bag and store it in a dry, ventilated place.
Disposal
Always adhere to national regulations when disposing of power tools that are no longer functional
and are not viable for repair.
• Do not dispose of power tools, or other waste electrical and electronic equipment (WEEE), with
household waste
• Contact your local waste disposal authority for information on the correct way to dispose of
power tools
Troubleshooting
Problem
Cause
Solution
The heat shuts ‘OFF’
but the fan stays ‘ON’
The fan is designed to run continuously while the heater is
operating; the thermostat is designed to switch ‘ON’ and
‘OFF’ to maintain the set temperature
The heater is operating correctly
The heating element is smoking
slightly and there is a
burning odour
The steel element’s protection oil coating is burning ‘OFF’
If this is the first time the heater has been used, this is normal and the amount of
smoke emissions will diminish in a short time. If it is a constant stream of smoke
and the heater has been used several times, immediately switch the heater ‘OFF’
and contact an authorised Silverline service centre
The heating element is not glowing
bright red like other heaters
The heating element is made from stainless steel and will
not glow bright red like other heaters
The heater is operating correctly
There is no heat or air
flow coming from the heater
The power to the heater has been shut ‘OFF’
Check the power being supplied to the heater. Unplug the heater and try a different
socket. If the heater does not work, contact an authorised Silverline service centre
The desired room temperature set on the
thermostat has been reached
The thermostat is working correctly and is designed to switch on and off to
maintain the set room temperature. The heater is operating correctly
The area directly in front of the heater is not being heated,
but the room generally is being heated
The heater is operating correctly. The thermostat will switch on and
off to maintain the set temperature
The fan maintains the same speed
when the settings are changed
The fan maintains the same speed when the Thermostat Dial
(6) and the Mode Selector Dial (5) are being changed
The heater is operating correctly. The fan is designed to maintain
the same speed when the controls are changed
The Mode Selector Dial (5) has been turned to the ‘OFF’
position but the fan is still running
Switch off power to the heater and contact an authorised Silverline service centre
300316_Manual.indd 8
21/09/2017 10:08
Summary of Contents for 300316
Page 2: ...2 1 2 3 5 6 4 7 8 10 9...
Page 3: ...silverlinetools com 3 2 2 30 Fig I Fig III Fig IV Fig II...
Page 4: ...4...
Page 15: ...Chauffage lectrique soufflant d atelier 2 kW 300316 15 silverlinetools com...
Page 21: ...Elektro Heizl fter f r die Heimwerkstatt 2 kW 300316 21 silverlinetools com...
Page 27: ...Calefactor industrial 2 kW 300316 27 silverlinetools com...
Page 33: ...Termoventilatore 2 kW 300316 33 silverlinetools com...
Page 39: ...2 Kw werkplaats ventilatorkachel 300316 39 silverlinetools com...
Page 45: ...Elektryczny termowentylator warsztatowy 2 kW 300316 45 silverlinetools com...