background image

 

Summary of Contents for SKBD110P

Page 1: ...1 Technical Manual and ReplacementPartsList BeverageDispenser Specifications Subject to Change Without Notice 1600 Xenium Lane North Minneapolis MN 55441 3787 Phone 763 923 2441 MODEL SKBD110P ...

Page 2: ...lowing factors must be observed When placing the unit on a counter the counter must be able to support a minimum of 100 pounds When placed on a counter the unit must be on the feet supplied If the feet are removed the unit will not operate properly and the warranty will be void There must be at least two inches of clear space above on the sides and behind the unit and open in front Correct serving...

Page 3: ...by removing the Valve Insert first then removing or installing the Cream Container The end of the tube may need to be cleaned daily with a clean cloth to prevent buildup which could affect the dispensing of product After loading the creamer press and hold the REFILL button for 3 seconds until the indicator flashes 00 Defrost The Silver King cream dispenser is a manual defrost unit The unit should ...

Page 4: ...3 ...

Page 5: ...4 ...

Page 6: ...5 REPLACEMENT PARTS LIST MODEL SKBD110P WHEN ORDERING REPLACEMENT PARTS PLEASE PROVIDE MODEL AND SERIAL NUMBERS ...

Page 7: ...e valve insert by pulling it straight up Cleaning Once removed the valve can be cleaned with a brush and warm soapy water or in a dishwasher The valve area in the dispenser should also be cleaned with a brush and warm soapy water Insert New Bag into Container Insert a new beverage bag into the container as shown Lock the tube into place at the bottom of the container ...

Page 8: ...centered to avoid kinking which could result in reduced product flow or leaking Install Valve Insert Push and hold valve slide while inserting the valve insert from above Cut Tube Cut the tube one inch below the valve Press REFILL Button Press and hold the REFILL button for 3 seconds display 00 to alert the dispenser that a new beverage bag has been installed ...

Page 9: ...ing 3 Restricted filter drier 4 Restricted capillary tube 5 Moisture in system 1 Call service technician 2 Call service technician 3 Call service technician 4 Call service technician 5 Call service technician Compressor short cycles 1 Erratic control thermostat 2 Faulty relay 3 Low voltage 4 Compressor draws excessive wattage 1 Call service technician 2 Call service technician 3 Contact power comp...

Page 10: ...an Beverage leaking or not flowing 1 Tube kinked 2 Valve stuck 1 Remove valve and pull tube straight through valve area 2 Clean valve and valve area or call for service Ordering Parts Service Contact Silver King Refrigeration at 800 328 3329 for technical assistance Model__________________ Serial No ___________________ Date Installed__________________ 33547 REVISION C ...