Installation
Adjusting the Air Diffusers.
The fan unit has multiple diffusers, Silvan units
are fitted with a 5+5 configuration. All of the
diffusers are fully adjustable in width, height
and angle.
The above illustration shows the adjustment of
each individual module (di nozzle).
Width:
Loosen the U-bolt (1) and slide the
inside RHS (2) to the desired width. Re-
tighten the
U-bolt.
Height:
Loosen the 8mm bolt (3) and slide
the tube outlet mount (4) to the desired
height.
Re-tighten the bolt.
Forward/Rearward tilt:
Loosen the bolt (3)
and rotate the tube outlet mount (4) to the
desired angle. Re-tighten the bolt.
Upward/Downward tilt:
Loosen the 2 Allen
head bolts (5) under the plastic outlet and tilt
to the desired angle. Retighten the bolts.