Command 0x12 FUNC_INFO
The FUNC_INFO command returns the firmware revision and patch revision for currently-loaded functional mode
firmware (AM and FM). The command is complete when the CTS bit (and optional interrupt) is set. This command
may only be sent in powerup mode.
Command
Response
Bit
7
6
5
4
3
2
1
0
CMD
0x12
Bit
7
6
5
4
3
2
1
0
STATUS
CTS
ERR
XX
RSQINT
RDSINT
ACFINT
STCINT
RESP1
FWMAJOR[7:0]
RESP2
FWMINOR1[7:0]
RESP3
FWMINOR2[7:0]
RESP4
PATCHH[7:0]
RESP5
PATCHL[7:0]
RESP6
FUNC[7:0]