![Silicon Laboratories Si475X Series Programming Manual Download Page 246](http://html1.mh-extra.com/html/silicon-laboratories/si475x-series/si475x-series_programming-manual_1272036246.webp)
A N 5 4 3
246
Rev. 0.9
Property 0x2101 AM_NB_INTERVAL
The AM_NB_INTERVAL property sets the interval in microseconds that original samples are replaced by
interpolated clean samples. The noise blanker can be disabled by setting the noise blanker detect threshold to
0.The CTS bit (and optional interrupt) is set when it is safe to send the next command. This property may only be
set or read in powerup mode.
Default: 4
AM_NB_INTERVAL
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
NB_INTERVAL[15:0]
0x0004
Bit
Name
Function
15:0
NB_INTERVAL[15:0]
Sets the interval in number of audio samples that original sam-
ples are replaced by interpolated clean samples.
Default is 4. Range is 1–40.