Parameter
Symbol
Test Condition
Min
Typ
Max
Unit
Output fall time, From 70%
to 30% of V
IO
t
IOOF
C
L
= 50 pF,
= STRONG,
= 0x6
—
1.8
—
ns
C
L
= 50 pF,
= WEAK,
= 0x6
—
4.5
—
ns
Output rise time, From 30%
to 70% of V
IO
t
IOOR
C
L
= 50 pF,
= STRONG,
—
2.2
—
ns
C
L
= 50 pF,
= WEAK,
= 0x6
—
7.4
—
ns
Note:
1. In GPIO_Pn_CTRL register
4.1.12 VMON
Table 4.21. VMON
Parameter
Symbol
Test Condition
Min
Typ
Max
Unit
VMON Supply Current
I
VMON
In EM0 or EM1, 1 supply moni-
tored
—
5.8
8.26
μA
In EM0 or EM1, 4 supplies moni-
tored
—
11.8
16.8
μA
In EM2, EM3 or EM4, 1 supply
monitored
—
62
—
nA
In EM2, EM3 or EM4, 4 supplies
monitored
—
99
—
nA
VMON Loading of Monitored
Supply
I
SENSE
In EM0 or EM1
—
2
—
μA
In EM2, EM3 or EM4
—
2
—
nA
Threshold range
V
VMON_RANGE
1.62
—
3.4
V
Threshold step size
N
VMON_STESP
Coarse
—
200
—
mV
Fine
—
20
—
mV
Response time
t
VMON_RES
Supply drops at 1V/μs rate
—
460
—
ns
Hysteresis
V
VMON_HYST
—
26
—
mV
BGM11S Blue Gecko
Bluetooth
®
SiP Module Data Sheet
Electrical Specifications
silabs.com
| Building a more connected world.