52
007-5841-001
6: Basic Troubleshooting and Chassis Service
3.
Lift the fan housing up and out of the chassis, see
Figure 6-6
for the GPU fan extraction
example. See
Figure 6-7 on page 53
for the mid-chassis fan extraction location.
4.
Disconnect the wiring to the fan assembly and lift it away from the server.
Figure 6-6
Remove/Replace GPU Fan Example