16
007-5841-001
2: Server Installation
•
The tabs can lock the server into place when installed and pushed fully into the rack, (its
normal operating position).
•
The tabs also lock the server in place when fully extended from the rack. This prevents the
server from coming completely out of the rack when pulled out for servicing.
Depress both tabs at the same time to fully remove the server from its rail mounting and extract it
from the rack.
Install the Server in a Rack
Warning:
The SGI Rackable C2110G-RP5 server weighs up to 57 lbs (25.9 kg) Always
use proper lifting techniques when your move the server. Always get the assistance of
another qualified person when you install the sever in a location above your shoulders.
Failure to do so may result in serious personal injury or damage to the equipment.
1.
Extend the outer rails as shown in
Figure 2-5 on page 17
.
2.
Align the inner rails of the chassis with the outer rails on the rack.
3.
Slide the inner rails into the outer rails, keeping the pressure even on both sides. When the
chassis has been pushed completely into the rack, it should click into the locked position.
4.
Optional screws are recommended to secure and hold the front of the chassis to the rack.
!
Summary of Contents for Rackable C2110G-RP5
Page 1: ...SGI Rackable C2110G RP5 System User Guide 007 5841 001 ...
Page 3: ...007 5841 001 iii Record of Revision Version Description 001 May 2012 First release ...
Page 4: ......
Page 10: ......
Page 22: ......
Page 27: ...Install the System into a Rack 007 5841 001 13 Figure 2 2 Separating the Rack Rails ...
Page 31: ...Install the System into a Rack 007 5841 001 17 Figure 2 5 Installing the Server in the Rack ...
Page 38: ......
Page 52: ......
Page 63: ...Power Supply 007 5841 001 49 Figure 6 4 Power Supply Remove Replace Example ...
Page 69: ...System Fans 007 5841 001 55 Figure 6 9 Front GPU Fan Assembly Example ...
Page 76: ......