Overview
007-5922-001
31
Control panel notes
:
•
Blink rate is ~1 Hz at 50% duty cycle.
•
It is also off when the system is powered off (S5) or in a sleep state (S1).
•
The power LED sleep indication is maintained on standby by the chipset. If the system is
powered down without going through the BIOS, the LED state in effect at the time of power
off is restored when the system is powered on until the has BIOS cleared it.
F
System Status
LED
Green
On
System ready/No alarm.
Blink
System ready, but degraded:
– Redundancy lost such as a pwr supply or fan fail.
– Non-critical temp/voltage threshold.
– Battery failure.
– Predictive power supply failure.
Amber
On
Critical Alarm: critical power modules failure,
critical fans failure, voltage (power supply), critical
temperature and voltage
Blink
Non-Critical Alarm: Redundant fan failure,
redundant power module failure, non-critical
temperature and voltage
Off
– Power off: System unplugged.
– Power on: System powered off and in standby, no
prior degraded\non-critical\critical state.
G
System Power
button with LED
Green
On
Power On/ACPI S0 state
Blink
Sleep/ACPI S1 state
Off
Power Off/ACPI S5 state
H
Hard Drive
Activity LED
Amber
On
Hard drives are available.
Blink
Hard drive activity detected.
Off
No hard drives are available.
Table 3-1
ISS3124-RP2 Control Panel Components and Functions
(continued)
Label
Button/LED
Color
Condition
Function
Summary of Contents for IS2224
Page 1: ...SGI NAS ISS3124 RP2 Server and IS2224 JBOD Setup Guide 007 5922 001 ...
Page 3: ...007 5922 001 iii Record of Revision Version Description 001 October 2013 First release ...
Page 4: ......
Page 8: ......
Page 24: ......
Page 44: ......
Page 56: ......
Page 60: ......
Page 66: ......
Page 68: ......
Page 72: ......