Booting Your System
73
Booting Your System
Boot your system by performing the following steps:
1.
Power on the system, as described in the preceding section, “Powering On the
System.”
2. Go the front the chassis module and insert the system key into the key switch,
located to the right of the module System Controller’s (MSC) display. Turn the key
switch to the On position (see Figure 5-9).
Note:
The MSC begins the power-on sequence. The green power-on LED, located
above the function buttons, lights to indicate that power has been applied to the
system midplane. The amber fault LED then lights to indicate that power has been
supplied to the MSC. The fault LED goes out when the MSC has successfully
initialized and the power-on tests have completed.
3. Repeat this process with additional modules as required.