SIGNALLING OF THE RECEIVER AND SUBSEQUENT PROCEDURES
EVENT
FIX LED
FLASHING LED
DESCRIPTION
A B C
YES
Alarm groups armed
PANIC
YES
Panic alarm (immediate triggering of sirens via PCK)
TECHNICAL ALARMS.
YES
smoke, gas, flood alarms according to the assigned and programmed detectors
DISPLAY
NUMBER OF DETECTOR
Identification of detector by number
TEST
YES
Control unit in TEST to check the system – sirens off
PROGRAMMING
YES
Control unit in PROGRAMMING
ENTRY DELAY
YES
Detector shown by number on display is delayed with 30”
EXCLUSION DETECTOR YES
Detector shown by number on display has been excluded
DUAL DETECTOR
YES
2 detectors working together in the zone shown on display
DOOR OPEN
YES
A protected door/window has been left open. Either close it or leave it as it is.
If left open it will not be protected any longer
ALARM MEMORY
YES
During last arming period, detector shown by display caused an alarm if no
intrusion occurred or a mistake has been made, call technical assistance
TAMPER
YES
Detector shown has been tampered: this event immediately causes an alarm
(low intensity if control unit disarmed). Check and call for technical assistance
BATTERY
YES
Detector shown needs battery to be replaced: some days of life is left.
Replace battery a.s.a.p.
R.F. NOISE
YES
Control unit has not correctly received supervision signalling of detector
shown. Make a TEST: if positive, the noise could be incidental thus irrelevant.
If signalling is often repeated, maybe detector has been installed at range-
limit or not correctly so it has to be moved. If detector does not work properly,
it is necessary to exclude it and call for technical assistance.
6 TEST OF THE SYSTEM
For trying out the system without any alarm activation use the green-red-white buttons of R-Evolution as follows:
red and green buttons: pressed together for about 1 sec. TEST modality will be activated: TEST led will light up
red and green buttons: in TEST modality, pressed together for about 1 sec. will exclude the selected detector
red and green buttons: in TEST modality, pressed together for about 10 sec. will cancel all scheduled remote controls
green button:
pressed in succession will allow reading of the events memory
white button:
pressed in succession will allow selection of the detector position (from 1 to 96)
red button:
pressed will end TEST modality and return to normal functioning
For checking the functionality of the system, stir the detectors one by one: a BEEP will be generated as well as a temporary lighting up of the
number of each detector which produced alarm. These TEST alarms will remain stored (up to 50), and for this reason can be checked by
interrogating the events memory in TEST. Notice: leaving the TEST status this memory storage will be automatically reset.
It is recomendable to carry out a test once a year.
NOTICE:
for correct testing of volumetric detectors 5011 PIR TOP and 5014 SILENT PIR it is necessary to empty the protected rooms (persons,
animals) at least 3 minutes before triggering off an alarm by entering the protected area.
In order to check the protected area each detector has to be set in TEST modality (see its instructions).
EXCLUSION OF WIRELESS DETECTORS
In case of failure of a detector it will be possible to temporarily exclude it from the system. With the control unit in TEST modality search for the
position of the detector by pressing in succession the white button on the remote control. Once the detector has been identified press both the red
and green buttons together; exclusion will be confirmed and led “DETECT. OMITTED” will appear. Repeating the operation the detector will return
to normal functioning.
PART 2 – INSTALLATION AND PROGRAMMING
7 TECHNICAL FEATURES of R-EVOLUTION (also see electrical scheme)
Supply:
10-14V CC
Consumption
: 40mA typical in stand by
Peripheral devices by radio:
up to 96 det up to 32 remote co 32 keypad codes
Radio reception:
dualband – sensibility -105db – frequencies >400MHz and >850MHz according to law but indicated approximately for safety
reasons. Radio range: 100 meters in free area and in condition of total absence of noise on the band. Indoors it may undergo significant reductions
caused by the position of the devices referred to the structure of the rooms a/o by radio-disturbs on the band. Before final installation
it will always be necessary to check the sufficiency of the radio ranges.
Timing
: activation delayed with 60” – entry delay 30” on those detectors scheduled in such way
Entry-Exit connections – Displays – Sizes – Weight - Protection and Temperature:
see illustrations and schemes below
8 REMARKS FOR A PROPER INSTALLATION
Any installation should take into account the different environmental conditions, and therefore requires professional skills and care. Mistakes in
course of installation may cause bad functioning of the system not due to the devices themselves.
Before starting up the installation it will be necessary to define the required functions as well as the type and position of the wireless detectors and
their division on 3 zones for partial activation: for this reason the chart on the last page should be filled out.
24h Zone
: the device has 2 permanent active zones where to schedule technical alarms/commands a/o panic-burglar alarms. The detectors or
remote controls with special functions (24h) will have to be scheduled on special channels.
The range of the remote controls may vary according to their position and to the way in which they are handled in transmission-phase: check the
most favourable conditions.
All physical obstacles produce loss of radio range. For verifying the power of the captured signal it is recomendable to use FIELD METER, placing
this device at the installation point of the control unit and making sure that the signals are captured at least in the yellow area. In case there should
not be any transmission from the system, the noise notified from the FIELD METER must not exceed the green area.