background image

12.  Repeat for each Fire Transmitter/Smoke Detector and CO 

detector installed weekly.

13.  Test all auxiliary transmitters in the same manner. Verify 

Correct ICON is displayed on front lens corresponding to the 
Medallion series transmitter tested.

14. Testing Complete.

• 

Mini Receiver TOP THREE LED’S are 

fl

 ashing at a 1.5HZ 

rate.

• 

Appropriate Mini Receiver RED FIRE or CO Alert is illumi-
nated.

• 

Bed Vibrator is Pulsing appropriate tactile code as listed in 
Optional Bed Vibrator Auxiliary Output section.

• 

Green LED Remains ON. Amber LED Remains OFF.

• 

Approximately 16 seconds after depressing Transmitter 
test switch Mini Receiver will Stop Flashing the Strobe, 
RED Fire or CO Light will go OUT, Bed Vibrator will no 
longer pulse.

• 

Silent Buddy will return to Idle/Receive condition.

Summary of Contents for MR1214-MC

Page 1: ...Document 108124 3126052 MINI RECEIVER Installation and Operation Manual Model MR1214 MC 418 MHZ RECEIVER ...

Page 2: ......

Page 3: ... under the top strobe lens The receiver is now ready to be programmed Programming NOTE All Medallion Transmitters will be required to be pro grammed to your new receiver The receiver leaves the factory with the memory cleared Apply power to the receiver as described in the Installation sec tion With the receiver powered press and hold the program button located at the back of the receiver case All...

Page 4: ...mitters that were stored in memory have been erased Release the program button and all previously learned transmitter codes will have been successfully erased Battery Backup Mode In the event of a main power loss or failure of the wall adapter the Mini Receiver will automatically enter into the battery backup mode The Mini Receiver has been tested to provide at least 24 Hours of Battery backup ope...

Page 5: ...astic housing away from the back at the bottom until the top lens discon nects 3 Hold the circuit board in place with one hand and remove the 2 pin white connector from the green battery pack by pulling it straight out 4 The battery is secured in place with double sided tape To remove the battery pack from the plastic case hold the 2 wire harness close to the battery pack and rock the pack back an...

Page 6: ...tectors CO detec tors IAW testing section 13 Battery replacement procedure completed LED Intensity Selection Located on the back of the receiver at the top is a switch that will allow the user to select the brightness or the Intensity of the LED s LED intensity High Medium and Low selections are avail able When making the selection of the LED brightness make sure the LED strobe is off and the rece...

Page 7: ...tter Smoke Detector or Fire Transmitter Three Short Pulses and One Long Pulse Continuous Short Pulses Mini Receiver Display Indications and ICON Color Carbon Monoxide Detector CO5 MC Transmitter detects a warning from the CO detector Smoke Detector or Fire Transmitter SD4 MC FA3 MC FA4 MC Transmitter detects a Smoke Fire warning CO Red Red Operational and Performance TESTING Test the MR1214 MC aft...

Page 8: ...apter Plug AC DC adapter into a 120VAC 60HZ wall outlet 4 Plug opposite side barrel style plug into the MINI Power input Jack 5 Turn Mini Receiver ON Observe the Green LED is illuminat ed 6 Remove the Barrel style power plug from the Mini Receiver and confirm the Green LED stays illuminated and that the Amber LED begins to blinks once every 10 seconds 7 Reinstall Barrel style Power Plug and verify...

Page 9: ...HREE LED S are flashing at a 1 5HZ rate Appropriate Mini Receiver RED FIRE or CO Alert is illumi nated Bed Vibrator is Pulsing appropriate tactile code as listed in Optional Bed Vibrator Auxiliary Output section Green LED Remains ON Amber LED Remains OFF Approximately 16 seconds after depressing Transmitter test switch Mini Receiver will Stop Flashing the Strobe RED Fire or CO Light will go OUT Be...

Page 10: ... Battery specified in marking Use of a different battery will have a detrimental effect on alarm operation Constant expo sures to high or low temperatures or high humidity mat reduce battery life Input Operating Ambient Temperature Range Operating Humidity Range Agency Listings 16Vdc 0 5A Max During Alert w Strobe High and VIB PJ in use 40 to 100 F 4 4 to 37 8 C 15 to 95 Relative Humidity non cond...

Page 11: ......

Page 12: ...el free to contact us You can reach us by phone at 800 572 5227 voice or TTY or by Email at technicalsupport silentcall com Limited Warranty Your Mini Receiver is warranted to be free of defects in material and workmanship for five years from the date of initial purchase During that time the unit will be repaired or replaced free of charge when shipped prepaid to Silent Call Communications This wa...