IM_FULL_65SL_REV-A
6
RED WIRE (2) — +12V POWER INPUT
Remove the two 20A fuses prior to connecting these wires and do not replace them until the satellite has been
plugged into the control module. These wires are the source of current for all the circuits the relay satellite will energize.
They must be connected to a high current source. Since the factory supplies (+) 12V to the key switch that is used to
operate the motor, it is recommended that these wires be connected there.
Note:
If the factory supplies two separate (+) 12V feeds to the ignition switch, connect one RED wire of the satellite to
each feed at the switch.
YELLOW WIRE – IGNITION 1 OUTPUT
Connect the YELLOW wire to the ignition 1 wire from the ignition switch. The ignition wire should receive “12 volts”
when the ignition key is in the
“ON”
or
“RUN”
and
“START”
or
“CRANK”
position. When the ignition is turned
“OFF”
,
the ignition wire should receive “0” voltage.
The YELLOW wire must be connected.
PINK WIRE – IGNITION 2 OUTPUT
Some vehicles have [2] ignition wires that must be power. Connect the PINK wire to the ignition 2 wire from the ignition
switch. The ignition wire should receive “12 volts” when the ignition key is in the
“ON”
or
“RUN”
and
“START”
or
“CRANK”
position. When the ignition is turned
“OFF”
, the ignition wire should receive “0” voltage. If the PINK wire is not
used, cap the end of the wire.
BROWN WIRE –ACCESSORY OUTPUT (HEATER /AC OUTPUT)
Connect the BROWN wire to the accessory wire in the vehicle that powers the climate control system.
An accessory wire will show + 12 volts when the ignition switch is turned to the
“ACCESSORY”
or
“ON”
and
“RUN”
positions, and will show 0 Volts when the key is turned to the
“OFF”
and
“START”
or
“CRANK”
position. There will often
be more than one accessory wire in the ignition harness. The correct accessory wire will provide power to the vehicle’s
climate control system. Some vehicles may have separate wires for the blower motor and the air conditioning compressor.
In such cases, it will be necessary to add a relay to power the second accessory wire.
RS232 TWO WAY SERIAL DATA PORT CONNECTION:
This connector is to be used for Serial Data communications with Fortin and ADS/idatalink
modules only! DO NOT CONNECT THIS TO ANY OTHER WIRING!
T