DISPOSAL

For correct disposal please refer to current standards.

INFORMATION FOR USERS OF PROFESSIONAL EQUIPMENT

From "Actuation of Directive 2012/19/EU regarding Waste Electrical and Elec-
tronic Equipment (WEEE)"

The symbol of a crossed waste bin found on equipment or its packing indicates that at the end of the
product’s useful life it must be collected separately from other waste so that it can be properly treated
and recycled.
In particular, separate collection of this professional equipment when no longer in use is organised and
managed:

a) directly by the user when the equipment was placed on the market before 31 December 2010 and the

user personally decides to eliminate it without replacing it with new equivalent equipment designed for
the same use;

b) by the manufacturer, that is to say the subject which was the first to introduce and market new equip-

ment that replaces previous equipment, when the user decides to eliminate equipment placed on the
market before 31 December 2010 at the end of its useful life and replace it with an equivalent product
designed for the same use. In this latter case the user may ask the manufacturer to collect the existing
equipment;

c) by the manufacturer, that is to say the subject which was the first to introduce and market new equip-

ment that replaces previous equipment, if it was placed on the market after 31 December 2010;

Suitable separate collection for the purpose of forwarding discarded equipment for recycling, treatment
or disposal in an environmentally friendly way helps to avoid possible negative effects on the
environment and human health and encourages re-use and/or recycling of the materials making up the
equipment.

The sanctions currently provided for by law shall apply to users who dispose of products in unauthorised
ways

.

Summary of Contents for Delta 2000 AY

Page 1: ...D413450XA vers 3 0 Operating manual EN...

Page 2: ...ghts reserved No part of this publication may be reproduced or used in any form or by any means photocopying microfilm or other without the written permission of SILCA S p A Edition march 2008 Printed...

Page 3: ...vironmental conditions 9 5 3 Positioning 9 5 4 Description of work station 10 5 5 Separate parts 10 5 6 Connection to the mains 10 6 REGULATION and USE of the MACHINE 11 6 1 Checking and setting 11 6...

Page 4: ......

Page 5: ...safely and efficiently CONSULTATION The contents of the manual are divided into sections relating to Ch Transport and handling 1 Description of machine and safety devices 2 3 4 5 Proper use of the mac...

Page 6: ...urther risks arising from the use of the DELTA 2000 AY key cutting machine PROTECTION AND SAFETY PRECAUTIONS FOR THE OPERATOR The DELTA 2000 AY key cutting machine is built entirely to standards The o...

Page 7: ...this will avoid knocks which could cause damage to the machine persons or things 1 3 Unpacking To remove the machine from the packing box carefully follow the illustrated instructions below Fig 4 Chec...

Page 8: ...utton E axis regulation grub screw E1 axis regulation locking screw E2 coded spacing device knob F tracer point F1 tracer point locking screw F2 adjusting nut F3 tracer point s group locking screw G c...

Page 9: ...device and a clamp for se curing the keys with a code device for adjusting inclination fig 5 page 4 The carriage B is fitted to the translation shaft and is moved manually by the operator It has been...

Page 10: ...el HSS MOTOR One speed single phase 230V 50Hz 1350 rpm 0 145 Kw SAFETY DEVICE standard with 230V key cutting machines on request for other voltages CLAMP rocker CARRIAGE MOVEMENT manual CARRIAGE RUN m...

Page 11: ...sumption of approx 0 19 kw and absorption of 1 5A The main parts of the electrical circuit are listed below 1 Safety device inlet 2 Safety main switch 3 Warning light 4 Wiring clip 5 Machine inlet 6...

Page 12: ...ement parts DELTA 2000 AY is supplied with a full range of accessories The accessories provided by Silca are all that is necessary to carry out the operations for which the machine is designed code D3...

Page 13: ...mage 5 2 Environmental conditions To ensure that the best use is m ade of the key cutting machine certain parameters must be borne in mind damp badly ventilated sites should be avoided the conditions...

Page 14: ...parate parts The detachable parts of the machine are packed separately and must be fitted to the DELTA 2000 AY by the operator as follows POWER CABLE First connect the safety device X to the key cutti...

Page 15: ...ng proceed as follows WARNING disconnect the machine from the mains 1 set up the coded spacing device fig 5 page 4 by means of the knob E2 so that the indicator 5 is aligned with position 2 fig 11 2 p...

Page 16: ...adjustment is necessary adjust axial gauging in the way described above Axial gauging regulation 5 loosen the screw F3 locking the tracer point unit fig 5 page 4 6 use the lateral brush J to turn the...

Page 17: ...first cut and the tip of the key This distance can be 3 or 5 mm fig 10 A To cut keys with 3 mm use mark 3 on the locator Fig 11 as a reference for positioning the key For 5 mm keys use mark 5 To code...

Page 18: ...ctions below never carry out maintenance or servicing with the machine switched on always remove the mains plug follow all the instructions in the manual to the letter use original spare parts always...

Page 19: ...tracer point 4 re gauge the machine as described in Ch 6 page 11 Fig 16 7 4 Replacing the fuses WARNING unplug the machine from the mains 1 detach the wiring from the machine plug 2 turn the key cutti...

Page 20: ...y the manufacturer that is to say the subject which was the first to introduce and market new equip ment that replaces previous equipment when the user decides to eliminate equipment placed on the mar...

Page 21: ...anufacturer or in the special Service Centres recommended by Silca On the back cover of this manual is a list of t he manufacturer s addresses listed below are the addresses of specialised Service Cen...

Page 22: ...following European Directives European Union DIRECTIVE 2006 42 CE Machines and with the EN 292 1 EN 292 2 Standards European Union DIRECTIVE 2004 108 CE Electromagnetic Compatibility and with the EN 5...

Page 23: ...SILCA S p A Via Podgora 20 Z I 31029 VITTORIO VENETO TV Tel 0438 9136 Fax 0438 913800 E mail silca silca it www silca biz Members of the Kaba Group...