4.3 Mounting the magnetic sensor
Alignment of the magnetic sensor
`
Take care that the magnetic sensor is aligned correctly in order to
ensure optimum sensing (see
Fig. 6
).
1. Mount magnetic tape (see chapter
4.2
).
2. Magnetic sensor can be fastened by using two bolts M3 over the elon-
gated holes (for the fastening dimensions refer to the Data Sheet). We
recommend to use the enclosed fixing screws and washer springs (fas-
tening torque design K = 0.25 Nm, design M+AM+ZM = 1 Nm).
LINEAR application: MSK5000 with MB500/1
1
Active side magnetic tape
2
Travel direction signal A before
B
3
Direction of outgoing cable
4
Admissible deviation of tape/
sensor
0.1 ... 2 mm reference point O, I
0.1 ... 1.5 mm reference point R
0.4 ... 1 mm reference point FR
5
Maximum alignment error
6
Admissable deviation middle of
tape/sensor
ref. O, I ±2 mm
ref. R, FR ±0.5 mm
7
Position of the reference point
relating to the marking on the
magnetic tape
8
Flexible reference mark for
design ZM, mounted by the cus-
tomer (see chapter
10
)
Fig. 6: Definition of the counting direction with magnetic tape and
assemblage sensor / magnetic tape, gap measure, tolerances
8
6
7
5
1
3
4
2
MBxxxx GEK WT RP NNNNNN
<1°
<3°
<3°
NOTICE