MSK320R
Trouble shooting English
MSK320R · Date
30.01.2018 · Art.
No.
88942 · Mod.
status
42/18
27
6 Trouble shooting
Below are some typical errors which may occur during installation and
operation:
•
Magnetic strip wrongly mounted, active side below (see chapter
4.2
).
•
The masking tape provided was not used for protecting the magnetic
strip. The masking tape must not be magnetizable.
•
Magnetic sensor not or incorrectly connected (pin assignment see
chapter
4.5
).
•
The distance tolerances were not observed over the whole measuring
length (see
Fig. 7
).
•
Cable squeezed / interrupted / cut by sharp edges.
•
The magnetic sensor has been mounted with the active side turned
away from the band (see
Fig. 7
).
•
Magnetic sensor has not been aligned according to
Fig. 7
7 Transport, Storage, Maintenance and Disposal
Transport and storage
Handle, transport and store the magnetic sensor with care. Pay attention
to the following points:
•
Transport and / or store the magnetic sensor in the unopened origi-
nal packaging.
•
Protect the magnetic sensor from harmful physical influences inclu-
ding dust, heat and humidity.
•
Do not damage connections through mechanical or thermal impact.
•
Prior to installation inspect the magnetic sensor for transport dama-
ges. Do not install damaged magnetic sensors.
Maintenance
With correct installation according to chapter
4
the magnetic sensor
requires no maintenance. Clean the surface of the magnetic strip with soft
cloth from time to time if it is very dirty.
Disposal
The magnetic sensor's electronic components contain materials that are
harmful for the environment and are carriers of recyclable materials at the
same time. Therefore, the magnetic sensor must be recycled after it has
been taken out of operation ultimately. Observe the environment protec-
tion guidelines of your country.