8 Diagnostic functions
With the error case "sensor-band gap exceeded" occurring, the RS422
driver's output will be switched high-impedance (signals A, /A, B, /B)
(only with LD version)!
Various diagnostic functions have been integrated into MSAC501.
A two-colour LED signals the actual error states. The states are differenti-
ated via the LED's colour and blinking rates. The signal is repeated after a
600 ms pause.
Error state
LED
Blinking rate
1. Sensor-band gap
red
1x
2. Plausibility absolute value
red
2x
3. Speed check (v >5 m/s)
red
4x
4. Sensor-tape alignment
green
1x
5. Verify error EEPROM
green
2x
6. Checksum error EEPROM
green
4x
7. Read/write error EEPROM
green
8x
If several error states occur at the same time, the relevant blinking sig-
nals will be added to form a sequence (e. g., red LED blinks 5x -> error sta-
tes 1 + 3).