MSA213C-S (BiSS/C)
BiSS C (bidirectional) interface English
MSA213C-S (BiSS/C) · Date 24.05.2022 · Art. No. 90036 · Mod. status 111/22
16
Set zero point
The current position is set as zero point value.
0
0
16383999
4000000
16383999
0
0
16383999
16383999
RS485 command Sxxxxx
-> SCZP (ASCI)
-> S00000
Tape encoding
Sensor position
value
Write calibration value (absolute offset) (from SW V4.0)
The current position is increased by the offset value.
0
0
16383999
4000000
16383999
0
0
16383999
16383999
RS485 command Fxyyyyyyyyyyyy
-> F1000001000000 writes offset value 1 m
Tape encoding
Sensor position
value
5000000
Write zero point value + calibration value (absolute offset) (from SW
V4.0)
The current position is set as zero point value and then increased by the
offset value.
0
0
16383999
4000000
16383999
0
0
16383999
16383999
RS485 command Gxxxxxxxxxx
-> G0001000000 sets zero point and
offset value 1 m
Tape encoding
Sensor position
value
1000000
5 BiSS C (bidirectional) interface
The sensor has a BiSS C (bidirectional) interface and can also be param-
eterized via this interface. For this purpose, individual registers can be
described or commands can be issued.