Communication via CAN bus (CANopen and CANopen Safety)
IKM360M
Date: 21.01.2021
Art. No. 90444
Mod. status 222/20
Page 32 of 58
Name
Description
See
page
6000h: Resolution
Resolution of the slope long16 value.
6010h: Slope long16
Slope long16 value (longitudinal slope).
6011h: Slope long16 operating
parameter
Operating parameter
6012h: Slope long16 Preset
value (calibration value)
Calibration value for longitudinal slope (slope
long16 preset value).
6013h: Slope long16 Offset
Application offset of the slope (slope long16
offset).
6014h: Differential Slope
long16 Offset
Specifies the offset of the slope long16 value.
6200h: Safety configuration
parameters
Safety calibration value for longitudinal slope
(Safety Slope long16 preset value).
6210h: Safety Slope long16
(Safety longitudinal slope
value)
Safety Slope long16 (Safety longitudinal slope
value).
6211h: Safety inverted Slope
long16 (Safety inverted
longitudinal slope value)
Safety inverted Slope long16 (Safety inverted
longitudinal slope value).
63FEh: Safety application
configuration
Activate Safety Slope long16 configuration.
63FFh: Safety application
configuration signature
(checksum)
Signature (checksum) via the CANopen Safety
parameters of the configuration for Safety Slope
long16.
Indicates the device temperature.
Table 17: Overview of objects
5.8.2
Object Description
5.8.2.1
1000h: Device Type
Object 1000h indicates the device profile number.
Sub-index
00h
Description
Information about the device profile and encoder type
Access
ro
PDO mapping
no
Data type
UNSIGNED 32
Default
3001019Ah
EEPROM
no
Data content
Device profile -number
Additional information
Byte 0
Byte 1
Byte 2
Byte 3
9Ah
01h
01h
30h
019Ah (= 410d): CANopen Device profile for inclinometer