SIKA TP 18 600 E Operating Instructions Manual Download Page 1

ba_tp18600e_e.doc/03/04/e

Version 0.2

Page 1

Operating instruction

Temperature calibrator TP 18 600 E

List of contents

Page

1   Description of the temperature calibrator TP 18 600 E....................................................................................... 2
2   Safty instructions ................................................................................................................................................. 2
3   Operation of the calibrator................................................................................................................................... 4
3.1   Adjustment of the handle ................................................................................................................................. 4
3.2   Operating position ............................................................................................................................................ 4
3.3   Adapter sleeves................................................................................................................................................ 4
3.4   Control of temperature sensors........................................................................................................................ 4
3.5   Front panel description..................................................................................................................................... 4
3.6   Switching on of the calibrator ........................................................................................................................... 5
3.7   Indication of the block temperature and set temperature ................................................................................ 5
3.8   Adjustment of the block temperature ............................................................................................................... 5
3.9   Programming of the set point ........................................................................................................................... 6
4   Cooling down the heating block .......................................................................................................................... 6
5   Recalibration ....................................................................................................................................................... 6
6   Error signalling .................................................................................................................................................... 6
7   Cleaning .............................................................................................................................................................. 6
8   Disposal............................................................................................................................................................... 7
9   Guarantee and repairs ........................................................................................................................................ 7
10   Technical Data .................................................................................................................................................. 7

Summary of Contents for TP 18 600 E

Page 1: ...of the handle 4 3 2 Operating position 4 3 3 Adapter sleeves 4 3 4 Control of temperature sensors 4 3 5 Front panel description 4 3 6 Switching on of the calibrator 5 3 7 Indication of the block tempe...

Page 2: ...0 E correspond to the current state of technology This refers to measuring accuracy function as well as safe operation of the devices To grant safe operation competent and responsible behaviour of the...

Page 3: ...t for applications not expressly permitted by the above mentioned rule must adopt all the necessary protective measures The instrument CANNOT be used in dangerous environments flammable or explosive w...

Page 4: ...ry to use exactly adapted pockets The right bore is the outer dameter of the device under test 0 5 mm 3 4 Control of temperature sensors For the test of temperature sensors a separate temperature meas...

Page 5: ...ating cartridge heats the brass block up from ambient temperature to the adjusted set point value 3 7 Indication of the block temperature and set temperature The red 4 digit 7 segment LED PV shows con...

Page 6: ...ument the installed fan starts to produce cool air which leads to a sufficient thermic decoupling of the enclosure For a quicker colling down of the heating block the fan can be switched to position 2...

Page 7: ...s found without any fees or charge for SIKA except in the event of alternative agreements 10 Technical Data Regulation of the heating block with PID regulator Adjustment of the block temperature with...

Page 8: ...ensation Storage temperature 10 60 C Compliance ECC directive EMC 89 336 EN 61326 ECC directive LV 73 23 and 93 68 EN 61010 1 Dimensions TP18600E TP18600 28E TP18600 200E TP18600 28 200E heating block...