Safety instructions  

 

Before you install the VMZ, read through this operating manual carefully. If the instructions 
contained within it are not followed, in particular the safety guidelines, this could result in 
danger for people, the environment, and the device and the system it is connected to. 

The VMZ correspond to the state-of-the-art technology. This concerns the accuracy, the op-
erating mode and the safe operation of the device. 
In order to guarantee that the device operates safely, the operator must act competently and 
be conscious of safety issues.  
SIKA provides support for the use of its products either personally or via relevant literature. 
The customer verifies that our product is fit for purpose based on our technical information. 
The customer performs customer- and application-specific tests to ensure that the product 
is suitable for the intended use. With this verification all hazards and risks are transferred to 
our customers; our warranty is not valid. 

Qualified personnel: 

 

The personnel who are charged for the installation, operation and maintenance of the 
VMZ must hold a relevant qualification. This can be based on training or relevant tuition.  
The personnel must be aware of this operating manual and have access to it at all times. 

 

The electrical connection should only be carried out by a fully qualified electrician. 

General safety instructions: 

 

In all work, the existing national regulations for accident prevention and safety in the 
workplace must be complied with. Any internal regulations of the operator must also be 
complied with, even if these are not mentioned in this manual. 

 

Degree of protection according to EN 

60529:

 

Please ensure that the ambient conditions at the site of use does not exceed the require-
ments for the stated protection rating (

 § 9 "Technical data"). 

 

Prevent freezing of the medium in the device with appropriate measures. 

 

Only use the VMZ if it is in perfect condition. Damaged or faulty devices must be checked 
without delay and, if necessary, replaced. 

 

When fitting, connecting and removing use only suitable appropriate tools. 

 

Do not remove or obliterate type plates or other markings on the device, as otherwise the 
warranty is rendered null and void. 

Special safety instructions: 

 

Crystallizing liquids:  
Liquids which crystallize when dried out can cause a malfunction of the VMZ. 

 

Make sure that the VMZ is not run dry. 

 

Prevent the crystallization of the fluid in the device by taking appropriate measures.  

 

Further warnings that are specifically relevant to individual operating procedures or activities 
can be found at the beginning of the relevant sections of this operating manual. 
 

 

Summary of Contents for induQ VMZ 030

Page 1: ...f the device is resold please provide the operating manual along with it SIKA Ba_VMZ_en 05 2016 Magnetic Inductive Flow Sensor Series VMZ Types VMZ 030 VMZ 081 VMZ 082 VMZ 153 VMZ 204 VMZ 205 VMZ 256...

Page 2: ...and off 11 6 3 Measuring operation 11 7 Maintenance and cleaning 12 7 1 Return shipment to the manufacturer 12 8 Disassembly and disposal 13 9 Technical data 14 9 1 Characteristics VMZ 14 9 2 Material...

Page 3: ...CAUTION Risk of injury This sign indicates dangers that cause personal injuries that can lead to health defects or cause considerable damage to property CAUTION Electric current This sign indicates da...

Page 4: ...n the front of the VMZ It contains the most important data and the connection dia gram for the electrical connection Example Fig 1 1 Delivery unpacking and accessories All units have been carefully ch...

Page 5: ...device supplied is only guaranteed by intended use The speci fied limits 9 Technical data may under no circumstances be exceeded Before installing the device check that the wetted materials of the de...

Page 6: ...must be aware of this operating manual and have access to it at all times The electrical connection should only be carried out by a fully qualified electrician General safety instructions In all work...

Page 7: ...el electrodes are located in the middle of the measuring tube between the earthing sleeves The VMZ does not need any moving parts to make measurements The inside of the measur ing tube is completely o...

Page 8: ...e equipment is depressurised and has cooled down SUITABLE TOOLS Use only suitable tools of the correct size 4 1 Installation instructions CAUTION Risk of malfunction due to external magnetic fields Ma...

Page 9: ...adjacent devices If adjacent devices are too close together operation of both devices may be impaired due to mutual interference 4 2 Assembly The VMZ is installed directly into the pipeline The compa...

Page 10: ...ize the electrical system before connecting the VMZ Connection and wiring Screw the coupling socket of the connection cable to the plug of the VMZ Tighten the knurled nut of the coupling socket with a...

Page 11: ...annot be switched on or off on its own Switching on and off is carried out by the applied supply voltage Switch on the supply voltage The red LED lights up permanently The VMZ is ready for use and goe...

Page 12: ...he operating company WARNING Risk of injury due to insufficient cleaning The operating company is responsible for all damages and harm of any kind in particu lar physical injuries e g caustic burns or...

Page 13: ...r to disassembly ensure that the equipment is switched off and is in a safe and de energised state the equipment is depressurised and has cooled down Disassembly Remove the electrical connectors Remov...

Page 14: ...10 0 12 5 Signal shape Square wave signal duty cycle 50 50 can be connected as PNP or NPN open collector Signal current 25 mA Electrical characteristics Supply voltage 24 VDC 15 or 12 VDC 15 Power co...

Page 15: ...nt Material Component wetted Housing ABS Measuring tube VMZ_ _ _ _ _DE_ _ _ _ _ _ VMZ_ _ _ _ _PE_ _ _ _ _ _ POM PVDF X Process connections VMZ_ _ _ _ _DE_ _ _ _ _ _ VMZ_ _ _ _ _PE_ _ _ _ _ _ POM PVDF...

Page 16: ...Technical data induQ Series VMZ 16 SIKA Ba_VMZ_en 05 2016 9 3 Pressure drop...

Page 17: ...l data Technical changes reserved 17 9 4 Dimensions VMZ DN 3 DN 8 DN 15 DN 20 Type L1 L2 D1 D2 VMZ 030 85 13 3 G B 3 VMZ 081 85 13 3 G B 8 VMZ 082 85 13 3 G B 8 VMZ 153 90 16 G B 14 VMZ 204 90 16 G1 B...

Page 18: ...Technical data induQ Series VMZ 18 SIKA Ba_VMZ_en 05 2016 VMZ DN 25...

Page 19: ...induQ Series VMZ Technical changes reserved 19 For your notes...

Page 20: ...05 2016 Sensors and Measuring Instruments Flow Measuring Instruments Test and Calibration Instruments SIKA Dr Siebert K hn GmbH Co KG Struthweg 7 9 D 34260 Kaufungen Germany 49 0 5605 803 0 49 0 5605...

Reviews: