EC mAV 2
Technical data
Technical changes reserved
- 45 -
9
Technical data
The technical data of customised versions may differ from the data in these instructions.
Please observe the information specified on the type plate.
Applicable to a temperature range from 18 °C to 28 °C, within one year after calibration.
9.1
Characteristics EC mAV 2
Characteristics
EC mAV 2
Output
DC mA generation
*1
-
Range
-
Output range
-
Resolution
-
Accuracy
20 mA
0…22 mA
0.001 mA
± (0.05 % + 4 µA)
Transmitter simulation
*2
-
Range
-
Output range
-
Resolution
-
Accuracy
-20 mA
0…22 mA
0.001 mA
± (0.05 % + 4 µA)
Loop supply
*3
-
Range
-
Accuracy
24 V
± 10 %
Input
Voltage
*4
-
Range
-
Output range
-
Resolution
-
Accuracy
28 V
-0.2…28 V
0.001 V
± (0.02 % + 2 mV)
Current
*5
-
Range
-
Output range
-
Resolution
-
Accuracy
20 mA
-1…22 mA
0.001 mA
± (0.02 % + 4 µA)
Loop current
*6
-
Range
-
Output range
-
Resolution
-
Accuracy
20 mA
0…22 mA
0.001 mA
± (0.02% + 4 µA)
*1 max. load 1
kΩ at 20 mA.
*2 max. load 1
kΩ
at 20 mA, power supply range 5…25 VDC.
*3 max output current up to 25 mA.
*4
input resistance about 1 MΩ.
*5
resistance about 20 Ω.
*6 providing 24 V loop supply.