5-50
DC2 % n
Print Drive User-Define
Code
12
16
+
25
16
+
n
Domain of
function
1
≤
n
≤
16
Function
Executes the printing according to the print drive defined by a user.
n = 1 : The amount of 1
×
8 dots
n = 16 : The amount of 16
×
8 dots
Details
•
When one line is printed, how many times the line is divided is determined
depending on the amount of n
×
8 dots.
Example) Suppose that the number of dots printed
=
128 dots, and n
=
1
128
÷
(1
×
8) = 16 (one line printed is divided into 16 parts)
•
The smaller the value of n, the lower the required electric power. And the bigger
the value of n, the faster the speed of printing.
DC2 ~ n
Print Density Set
Code
12
16
+
7E
16
+
n
Domain of
function
0
≤
n
≤
255
Function Sets the print density
Details
•
n means n %.
•
When adjusting the print density double for low heat sensitive paper, set n = 200.
•
The print density cannot be set for each character.
•
In default, n
=
100.