DLE EOT n
Status Transmit in Real Time
Code
10
16
+
04
16
+
n
Domain of
function
n
=
1
Function Returns the current printer status in real time.
Details
•
Regardless of the validity of the automatic status response, this function returns
the current status.
•
For the status values, refer to
Table 5-1 Status Response Value Table
.
•
This command is executed at the reception.
•
When the real time command is invalid, this command is ignored.
•
Users should be aware that even if this command is valid and consistent with
DLE ENQ 1 in the image data, this command will be executed.
Table 5-1 Status Response Value Table
Description
Response value
(1 byte)
Printer status
0 1
Bit 0
Out-of-paper error
no error
error
Bit 1
Cover open error
no error
error
Bit 2
Voltage error
no error
error
Bit 3
Temperature error
no error
error
Bit 4
Printer operation
standby
operating
Bit 5
Fixed to 1
−
fixed
Bit 6
Fixed to 1
−
fixed
Bit 7
Fixed to 0
fixed
−
*
:This bit is valid only for DLE EOT. The value is fixed at 0 for the other commands.