5-38
9. Bitimage
commands
ESC
∗
m nl nh [d1...dk]
Bitimage
Select
Code
1B
16
+
2A
16
+
m
+
nl
+
nh
+
[d1...dk]
Domain of
function
m
=
0,1,32,33
0
≤
nl
≤
255
0
≤
nh
≤
3
0
≤
d
≤
255
Function Specifies the Bitimages with the number of dots specified as nl and nh in Mode m.
m Mode
The number
of dots in
the vertical
direction
The number of
dots in the
horizontal
direction
(1 line)
The number of
data (k)
0
8 dot single density
8
192
nh
×
256 + nl
1
8 dot double density
8
384
nh
×
256 + nl
32
24 dot single density
24
192
(nh
×
256 + nl)
×
3
33
24 dot double density
24
384
(nh
×
256 + nl)
×
3
Details
•
If m is out of the domain of function, the data after nl is processed as the normal
data.
•
nl and nh mean the number of dots in the horizontal direction of the Bitimage to
be printed.
•
If the dot is specified beyond the printable area, the data is deleted.
•
The data deployment position corresponds to the deployment start position.
•
This command is affected by the inverse print but the others such as dual print,
bold print and reverse print.
•
Refer to the diagram for how to deploy the data.