Sigrand IPhouse-15E/IR User Manual Download Page 10

The 

th power

 command displays the current setting of the heating power.

:th power
50%

Note: the same LEDs are used for lighting and for heating, but the power assigned for heating may differ 

from the power assigned for lighting.

5.5.3.4 Setting Temperature Thresholds

If the thermostat is enabled, the LEDs are turned on when the internal temperature falls down to the  

lower threshold, and are turned off when the internal temperature rises up to the upper threshold.

The 

th ton N

 command sets the lower temperature threshold. The 

N

 is a signed integer value in 

°C

.

:th ton 0

The 

th toff N

 command sets the upper temperature threshold.

:th ton 10

The commands 

th ton 

and 

th toff 

display the current settings for the temperature thresholds.

:th ton
+0'C
:th toff
+10'C

5.5.3.5 Saving Thermostat Settings

The 

th save

 command saves the current thermostat settings to the EEPROM.

:th save
OK

5.5.4 Preheat Control Command – 

ph

The preheat is the feature that allows to delay the camera startup until the internal temperature reaches 

the specified threshold. It allows the camera to avoid operating at the temperature which is out of the camera's 

ratings.

Note: Preheat is not functional in the PoE chain configuration and should not be enabled.

5.5.4.1 Preheat Monitoring

The 

ph

 command displays the state of the preheat.

:ph
Preheat: ON Power=100% Temp=+18'C Heater: OFF

The first parameter (

ON

 or 

OFF

) shows whether the preheat feature is enabled or not. 

The 

Power=

 parameter is the actual setting for the LEDs power used during the preheat.

The 

Temp=

 parameter is the internal temperature.

The last parameter displays the state of the heater (

ON

 or 

OFF

). 

5.5.4.2 Enabling Preheat Feature

The 

ph on

 command enables the preheat feature, the 

ph off

 command disables it.

:ph on
:ph off

5.5.4.3 Setting Power for Preheat

The 

ph power

 

N

 command sets the power of the LEDs for the preheat in %.

:ph power 100

The 

ph power

 command displays the current setting of the preheat power.

:ph power
100%

Note: The preheat power can be set higher because the camera is off and does not consume power.

5.5.4.4 Setting Target Temperature

If the preheat is enabled, at the power up the camera is off and the Heater is on. When the internal 

temperature reaches the target value, the heater is turned off and the camera is turned on.

10

Summary of Contents for IPhouse-15E/IR

Page 1: ...nal and external temperature as well as remote power feeding parameters The IPhouse 15 is controlled by the Command Line Interface CLI The IPhouse 15 can be supplied in several configurations IPhouse...

Page 2: ...op Table 5 PoE Characteristics Recommended Parameter Value Units Total Power Consumption max 15 W PoE Class 3 Camera Power Consumption max 7 W Camera PoE Class 2 Table 6 Default Settings Parameter Val...

Page 3: ...support 4 1 4 Attach the support to the camera by means of the nut and the screw 1 4 1 5 Insert the camera into the housing and fix it by the thumbscrews 4 2 Serial Port Connection 4 2 1 If the camer...

Page 4: ...short Ethernet patch cord 4 5 PoE Chain LAN Connection A camera with two Ethernet ports and PoE chain capability should be used to make a PoE chain The housing has no PoE chain capability itself In s...

Page 5: ...ng temperature and illuminance On Off thresholds Monitoring temperature illuminance and consumed power Accessing by SSH through camera s serial port or by a terminal 5 2 Accessing CLI through Camera s...

Page 6: ...IPhouse 15 Console Cable Annex A to the console port of the IPhouse15 device XP7 Attach DB 9F connector of the Cable to the COM port of your PC 5 3 2 Setting up HyperTerminal Run the HyperTerminal Pro...

Page 7: ...st command can be edited 5 4 4 Error Messages If the entered command is not a valid command the device answers with the Unknown command message abcd Unknown command If the command has arguments and on...

Page 8: ...emperature sensor 5 5 2 2 Controlling LEDs The LEDs can be controlled manually of automatically The commands led on and led off are intended for the manual control The led on command turns on the LEDs...

Page 9: ...tting of the power backoff led pbo 50 Warning Changing these setting may affect the LEDs lifetime 5 5 2 6 Saving LEDs Settings The led save command writes the current LEDs settings to the EEPROM led s...

Page 10: ...d It allows the camera to avoid operating at the temperature which is out of the camera s ratings Note Preheat is not functional in the PoE chain configuration and should not be enabled 5 5 4 1 Prehea...

Page 11: ...ng is not functional Icam and Icam are always 0 5 5 5 2 Controlling Camera The cam auto command enables the automatic controlling the camera The automatic mode is used only for the preheat feature see...

Page 12: ...nitoring power The power command displays the total power consumed by the device including the camera power V 50 9V I 181mA P 9 23W The command displays three parameters The V parameter is the PoE vol...

Page 13: ...olution 1 Disconnect the camera or the LEDs physically to allow the device to start successfully Reduce the power settings or restore the default settings by the default command Connect back the camer...

Page 14: ...6 Annex A Table 7 IPhouse 15 Console Cable Pinout BLS 2 IPhouse 15 Pins Network DB 9F COM port Pins 1 TXD 3 2 RXD 2 3 GND 5 4 DTR 4 14...

Reviews: