SignitePro C18000CLF Manual Download Page 2

2

TABLE OF CONTENTS

WARNING:  Read the installation & operating manual completely before using this        

appliance.  IMPORTANT: Read all instructions and warnings carefully before starting     

installation.  Failure to follow these instructions may result in possible injury to persons 

or a fire hazard and will void warranty.

PRODUCT SPECIFICATIONS - 2

IMPORTANT SAFETY INFORMATION - 3

PRODUCT FEATURES - 5

PREPARING FOR INSTALLATION - 6

INSTALLATION - 10

OPERATION - 18

CARE AND MAINTENANCE - 23

TROUBLESHOOTING - 24

REPLACEMENT PARTS LIST - 27

WARRANTY - 28

PRODUCT SPECIFICATIONS

SERIES

CA20000B

CA20000BF

CA20000BL

CA20000BLF

CA18000C

CA18000CF

CA18000CL

C18000CLF

Maximum 

BTU/hr 

20,000

20,000

20,000

20,000

24,500

24,500

18,000

18,000

Fuel Type 

Natural Gas

Natural Gas

Propane

Propane

Natural Gas

Natural Gas

Propane

Propane

Ignition 

Electronic 

Push Button

Electronic 

Push Button

Electronic 

Push Button

Electronic 

Push Button

Electronic 

Push Button

Electronic 

Push Button

Electronic 

Push Button

Electronic 

Push Button

INLET GAS PRESSURE

Manifold

Pressure 

6 in W.C

6 in W.C

10 in W.C

10 in W.C

6 in W.C

6 in W.C

10 in W.C

10 in W.C

Maximum

Pressure

9 in W.C

9 in W.C

14 in W.C

14 in W.C

9 in W.C

9 in W.C

14 in W.C

14 in W.C

*Minimum

(*For 

purposes of

input

adjustment) 

7 in W.C

7 in W.C

11 in W.C

11 in W.C

7 in W.C

7 in W.C

11 in W.C

11 in W.C

Dimensions 

(in.) 

( H x W x D)

(Height

includes 

legs) 

20.5 × 24 × 7

20.5 × 24 × 7

20.5 × 24 × 7

20.5 × 24× 7

20.5 × 24 × 7

20.5 × 24 × 7

20.5 × 24 × 7

20.5 ×2 4 × 7

Fan Ratings

---

110-120V

60Hz

23W

1400rpm

---

110-120V

60Hz

 23W

1400rpm

---

110-120V

60Hz

23W

1400rpm

---

110-120V

60Hz

23W

1400rpm

Summary of Contents for C18000CLF

Page 1: ...oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air For Combustion and Ventilation section on page 7 of this manual INSTA...

Page 2: ...4 500 24 500 18 000 18 000 Fuel Type Natural Gas Natural Gas Propane Propane Natural Gas Natural Gas Propane Propane Ignition Electronic Push Button Electronic Push Button Electronic Push Button Elect...

Page 3: ...ter will remain hot for a time after shutoff Allow surfaces to cool before touching WARNING Make sure any panel safety screen or guard removed for servicing an appliance is replaced prior to operating...

Page 4: ...in a bedroom These units are not approved for bathroom use 3 This heater needs fresh air ventilation to run properly This heater has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shut...

Page 5: ...ner on and off to maintain a desired room temperature For further information see page 19 State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth o...

Page 6: ...Water vapor is a by product of gas combustion An unvented room heater produces approximately one 1 ounce 30 mL of water for every 1 000 BTU 3 Kw of gas input per hour An unvented room heater is inten...

Page 7: ...LLY TIGHT CONSTRUCTION The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of unusually tight construction you must provide add...

Page 8: ...as heater ___________ BTU hr Gas heater logs ___________ BTU hr Other gas appliances ___________ BTU hr Total ___________ BTU hr Do not include direct vent gas appliances Direct vent draws combustion...

Page 9: ...se items directly to the outdoors or spaces open to the outdoors These spaces include attics and crawl spaces Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Air for Combustion and Ventilation fo...

Page 10: ...oining wall than required CAUTION This heater creates warm air currents These currents move heat to wall surfaces next to the heater Installing the heater next to vinyl or cloth wall coverings or oper...

Page 11: ...cle DO NOT dispose of batteries in fire Improper disposal may cause batteries to leak or explode PREINSTALLED FAN OPTIONAL WARNING This appliance is equipped with a three prong grounding plug for your...

Page 12: ...its wire connected to the receptacle mounting screw ACCESSING FAN 1 Turn off gas supply to appliance 2 Remove appliance from mounted position if applicable 3 Remove screws connecting rear heater cove...

Page 13: ...13 INSTALLATION GREEN BLACK WHITE POWER CORD FAN WIRING ASSEMBLY DIAGRAM MOTOR ELECTRICAL SCHEMATIC...

Page 14: ...r will be placed for leg installation to prevent scratching of the table and or the heater Set back of heater on table with the bottom of heater extending outside the table edge Fasten Support Legs to...

Page 15: ...INES MAYBE IN WALL Before cutting drilling or hammering verify their location If needed contact your electrician plumber or service person WALL MOUNTING Fig 11 Insert Rawl Plugs into wall after drilli...

Page 16: ...line pressure is higher the unit will not work and heater regulator damage could occur CAUTION Never connect the heater directly to a LP supply This heater requires an external regulator not supplied...

Page 17: ...5 kPa Leak Testing Heater Gas Internal Connections 1 Open equipment shutoff valve see Fig 13 2 Make sure control knob of the heater is in the OFF position 3 Open gas supply tank valve LP systems 4 Che...

Page 18: ...y to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If y...

Page 19: ...hts The pilot is visible centered below the burner behind the front grill see Fig 16 Do not attempt to light the pilot by hand 7 Keep control knob depressed for 30 seconds after pilot lights Release c...

Page 20: ...cool which shuts the heater off If pilot flame pattern is incorrect turn heater off see To Turn Off Gas to Appliance on page 20 see Troubleshooting pages 24 through 26 Ignitor Control Knob OFF P I L O...

Page 21: ...me Fig 23 Incorrect Abnormal Flame Pattern with tall flames with Control Knob Set to High Flame Infrared Flame Glass 1 2 Height Glass 1 2 Height Fig 20 Correct Normal Flame Pattern with short flames w...

Page 22: ...f the barrier becomes damaged the barrier shall be replaced with the manufacturer s barrier for this appliance OPERATION Fig 26 Viewing Glass Warning Label WARNING Never operate the appliance without...

Page 23: ...free of dust and debris NOTE The fan motor is pre lubricated for extended bearing life and requires no further lubrication WARNING Turn off heater and let cool before servicing CAUTION You must keep t...

Page 24: ...lectrode is positioned wrong 2 Ignitor electrode is broken 3 Ignitor electrode is not connected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Bad ignitor or ignition mod...

Page 25: ...burner s 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contact your gas supplier 2 Clean burner orifice see Care and Maintenance on page 23 or contact customer service Burner backfiring...

Page 26: ...ontrol valve is defective 1 Locate and correct all leaks see Checking Gas Connections on page 17 2 Contact customer service Moisture condensation noticed on windows 1 Not enough combustion ventilation...

Page 27: ...Burner Assembly Infrared 1 1 1 1 3 1 ODS LP Propane Pilot 1 1 1 1 3 2 ODS NG Natural Gas Pilot 1 1 1 1 4 Ignition Wire 1 1 1 1 1 1 1 1 5 1 Thermostatic Gas Valve 1 1 5 2 Thermostatic Gas Valve 1 1 5 3...

Page 28: ...sponsible for any incidental indirect or consequential damages except as provided by law 6 All other warranties expressed or implied with respect to the product its components and accessories or any o...

Reviews: