3

ASW25 & ASW75

www.stonco.com

www.keene-lighting.com

5.) According to your embedded 

terminal box, punch the corresponding 

mounting holes out of the light fixture. 

Punch the 

mounting holes

6.) Tear off the adhesive paper on the 

waterproof pad and stick the waterproof 

pad onto the back of the power supply 

housing. 

7.) Pull the input line wires from the 

embedded junction box through the 

fixture base and screw the base into the 

embedded junction box. 

Waterproof pad 

Power supply

housing

Screw

9. Screw the case closed with a screwdriver.  

10. Install the heatsink assembly and tighten the 

screws and fixing knob with a screwdriver to 

complete the installation. 

8. Install the upper half of the power supply housing 

by sliding the hinges together. Then, connect the 

incoming Line, Neutral, and Ground wires to the 

fixtures outgoing  Line, Neutral, and Ground wires. The  

purple and gray dimming wires from the driver will be 

left disconnected. Adjust the wattage and color 

temperature if needed. 

Input lines

Red (LED+)

Black (LED

-)

White (LED

-)

Line (Black)

Neutral (White)

Ground (Green)

Gray (DIM

-)

Purple (DIM+)

CCT Selectable 

DIP Switch

Wattage Selectable 

DIP Switch

Installation Instructions

Summary of Contents for Stonco KEENE ASW25-SCT-G1-10-BZ

Page 1: ...Do not restrict fixture ventilation Allow for some volume of airspace around luminaire Avoid covering luminaire with insulation foam or other material that will prevent convection or conduction coolin...

Page 2: ...the specified voltage range of the luminaire shown on the label i e 120 347V Make all electrical and grounded connections in accordance with the National Electrical Code and any applicable local code...

Page 3: ...ording to the label on the switch the default color temperature is 4000K Switch the dial to the left to 3000K to the right for 5000K or leave it in the middle for 4000K The default power switch is in...

Page 4: ...supply housing Screw 9 Screw the case closed with a screwdriver 10 Install the heatsink assembly and tighten the screws and fixing knob with a screwdriver to complete the installation 8 Install the up...

Page 5: ...ppareil pr voyez de l espace libre autour du luminaire vitez de recouvrir le luminaire avec de l isolant de la mousse ou un autre mat riau qui emp cherait de refroidir l appareil par convection ou con...

Page 6: ...indiqu sur l etiquette ex 120 347V Effectuer tous les connections lectriques et de mise la terre selon les exigences du code de l lectricit national et tous les exigences des codes locales Tous les co...

Page 7: ...t est 4000K Mettez le bouton de r glage gauche pour 3000K et droite pour 5000K Le s lecteur de puissance peut tre mit gauche pour 60W ou 20W d pendant sur le mod le au milieu pour 45W ou 15W ou droite...

Page 8: ...imentation 9 Visser les couvercle en place 10 Installer le dissipateur de chaleur et serrer les vis et le bouton de fixation pour compl ter l installation 8 Installer la partie sup rieur de la compart...