INSTALLATION INSTRUCTIONS
PowerForm Area & Flood
PN:443560815050
Rev: C
SlipFitter (SF)
Page 5 of 6
Signify Canada Ltd./Signify Canada Ltée.
281 Hillmount Road,
Markham, ON, Canada L6C 2S3
Signify North America Corporation
200 Franklin Square Drive
Somerset N.J. 08873, USA
© 2018 Signify Holding. All rights reserved. This document contains information relating to the product portfolio
of Signify which information may be subject to change. No representation or warranty as to the accuracy or
completeness of the information included herein is given and any liability for any action in reliance thereon is
disclaimed. The information presented in this document is not intended as any commercial offer and does not
form part of any quotation or contract. All trademarks are owned by Signify Holding or their respective owners.
www.gardcolighting.com
SF
-
SlipFitter Arm Mounted on HORIZONTAL Mast Arm requires a
3/8
-
16”
x 3
-
1/2 bolt thru
Splice Area
SlipFitter Arm
Mast Arm (by others)
(2) #8
-
32 screws,
Splice Cover and Gasket.
(4) 1/2
-
13”
Allen
Socket Head bolts
STEP 7:
Holding routed wires in splice area, carefully slip luminaire onto
the Mast Arm. Check to insure that wires are not pinched be-
tween inside of SlipFitter Arm and the Mast Arm and that lumi-
naire lead wires rotate freely.
STEP 8:
Install the 3/8
-
16 x
3
-
1/2”
bolt thru the SlipFitter and Mast Arm,
Install 3/8
-
16 Hex with Nylock nut to the end of the bolt and
tighten the bolt to 20 ft.
-
lbs. Fig. 6. Insure wires are not pinched
by the bolt.
STEP 9:
Level luminaire by adjusting engagement of
(4) 1/2
-
13”
Allen
Socket Head bolts and re
tighten the bolts to 43 ft.
-
lbs. Fig. 7
Fig. 5
Luminaire
Fig. 6
3/8
-
16 x
3
-
1/2”
bolt
3/8
-
16”
Hex Nut
with Nylock
Fig. 7
(4) 1/2
-
13 Allen
Socket Head bolts